BA7622F, BA7623F
Technical Note
●Measurement methods and conditions (BA7622F)
Parameter
Symbol
IN1
SWA
IN2
SWB
IN3
SWC
OUT1
SWD
OUT2
SWE
OUT3
SWF
Conditions
Circuit current
Icc
3
3
3
×
×
×
-
Vom12
1
3
3
3
×
×
Maximum output level
Vom22
3
1
3
×
3
×
*1
Vom32
3
3
1
×
×
3
Gv12
1
3
3
3
×
×
Voltage gain
Gv22
3
1
3
×
3
×
*2
Gv32
3
3
1
×
×
3
f12
1
3
3
3
×
×
Frequency characteristic
f22
3
1
3
×
3
×
-
f32
3
3
1
×
×
3
CT112
1
3
3
×
3
×
CT113
1
3
3
×
×
3
Interchannel crosstalk
CT211
3
CT213
3
1
1
3
3
3
×
×
×
×
3
-
CT311
3
3
1
3
×
×
CT312
3
3
1
×
3
×
Input impedance
ZIN3
3
3
4
×
×
×
*3
THD12
1
3
3
3
×
×
Total harmonic distortion
THD22
3
1
3
×
3
×
*4
THD32
3
3
1
×
×
3
×:Switches 1, 2, and 3 can be
* 1:Maximum output level
Connect a distortion meter to the output. Apply a f=1 kHz, 1 Vp-p sine wave to the input and adjust the input level so that the output distortion becomes 1.0%.
The maximum output level Vom (Vp-p) is the output voltage at that time.
* 2:Voltage gain
Apply a f=1MHz, 2.0 Vp-p sine wave to the input.. The voltage gain GV=20log[VOUT/VIN] (dB).
* 3:Input resistance
MTheeasinupreutthreesiisntpauntcpeinZ=vo( lVtaINg5e0V- IVN5IN00,)/w5h0e×n1500-6
μA is
[Ω].
injected
at
the
input
pin.
Measure
the
open
voltage
VIN0
of
the
input
pin.
* 4:Total harmonic distortion
Apply a f=1kHz, 1.0 Vp-p sine wave to the input and measure by connecting a distortion meter to the output.
●Measurement methods and conditions (BA7623F)
Parameter
Symbol
IN1
SWA
IN2
SWB
IN3
SWC
OUT1
SWD
OUT2
SWE
OUT3
SWF
Conditions
Circuit current
Icc
3
3
3
×
×
×
-
Vom12
1
3
3
3
×
×
Maximum output level
Vom22
3
1
3
×
3
×
*1
Vom32
3
3
1
×
×
3
Gv12
1
3
3
3
×
×
Voltage gain
Gv22
3
1
3
×
3
×
*2
Gv32
3
3
1
×
×
3
f12
1
3
3
3
×
×
Frequency characteristic
f22
3
1
3
×
3
×
-
f32
3
3
1
×
×
3
CT112
1
3
3
×
3
×
CT113
1
3
3
×
×
3
Interchannel crosstalk
CT211
3
1
3
3
×
×
CT213
3
1
3
×
×
3
-
CT311
3
3
1
3
×
×
CT312
3
3
1
×
3
×
THD12
1
3
3
3
×
×
Total harmonic distortion
THD22
3
1
3
×
3
×
*3
THD32
3
3
1
×
×
3
DG1
2
3
3
1
×
×
Differential gain (DG)
DG2
3
2
3
×
1
×
-
DG3
3
3
2
×
×
1
DP1
2
3
3
1
×
×
Differential phase (DP)
DP2
3
2
3
×
1
×
-
DP3
3
3
2
×
×
1
×:Switches 1, 2, and 3 can be
* 1:Maximum output level
Connect a distortion meter to the output. Apply a f=1 kHz, 1 Vp-p sine wave to the input and adjust the input level so that the output distortion becomes 1.0%.
The maximum output level Vom (Vp-p), is the output voltage at that time.
* 2:Voltage gain
Apply a f=1MHz, 2.0 Vp-p sine wave to the input. The voltage gain is calculated as follows: GV=20log[VOUT/VIN] (dB)
* 3:Total harmonic distortion
Apply a f=1kHz, 1.0 Vp-p sine wave to the input and measure by connecting a distortion meter to the output.
www.rohm.com