Product Specification
AU OPTRONICS CORPORATION
Note 4: Definition of contrast ratio (CR):
Brightness on the Whitestate
Contrast ratio (CR)= Brightness on the Blackstate
G121SN01 V3
Note 5: Definition of response time:
The output signals of photo detector are measured when the input signals are changed from Whiteto Black
(falling time) and from Blackto White(rising time), respectively. The response time interval is between 10% and
90% of amplitudes. Please refer to the figure as below.
%
Tf
Tr
100
90
Optical
response
W hite
10
0
Black
White
Note 6: Definition of viewing angle
Viewing angle is the measurement of contrast ratio 10, at the screen center, over a 180 ° horizontal and 180°
vertical range (off-normal viewing angles). The 180 ° viewing angle range is broken down as below: 90 ° (θ)
horizontal left and right, and 90 ° (Φ) vertical high (up) and low (down). The measurement direction is typically
perpendicular to the display surface with the screen rotated to its center to develop the desired measurement
viewing angle.
PDF created with FinePrint pdfFactory Pro trial version www.pdffactory.com
G121SN01 V3 rev.0.0
8/27