DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DCM40 データシートの表示(PDF) - Honeywell International

部品番号
コンポーネント説明
メーカー
DCM40 Datasheet PDF : 21 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
20
Mechanical pressure switches
Definitions
Definitions
Pressure data
Overpressure P ressure over the relevant atmospheric pressure. The reference point is
atmospheric pressure.
Vacuum P ressure under the relevant atmospheric pressure. The reference point is
atmospheric pressure.
Absolute pressure Overpressure relative to absolute vacuum.
Differential pressure Difference in pressure between 2 pressure measuring points.
Relative pressure Overpressure or vacuum relative to atmospheric pressure.
Pressure data in all FEMA documents refers to relative pressure.
That is to say, it concerns pressure differentials relative to atmospheric pressure.
Overpressures have a positive sign, vacuums a negative sign.
Permissible working pressure (maximum permissible pressure)
The maximum working pressure is defined as the upper limit at which the operation, switching reliability
and water tightness are in no way impaired (for values see Product summary).
Bursting pressure (test pressure)
Type-tested products undergo a pressure test certified by TÜV affirming that the bursting pressure
reaches at least the values mentioned in the Product summary. During the pressure tests the measuring
bellows are permanently deformed, but the pressurized parts do not leak or burst. The bursting pressure
is usually a multiple of the permissible working pressure.
Setting range
Pressure range in which the cutoff pressure can be set with the setting spindle.
Pressure units
Unit
bar
mbar
Pa
kPa
1 bar
1 mbar
1 Pa
1 kPa
1 MPa
1
0.001
10-5
0,01
10
1000
1
0.01
10
104
105
100
1
1000
106
100
0.1
0.001
1
1000
In FEMA documents pressures are stated in bar or mbar.
MPa
(psi) Ib/m2
0.1
10-4
10-6
0.001
1
14.5
0.0145
1.45  · 10-4
0,145
145
Pressure data for a pressure
switchbased on the example
of DWR625:
Setting range: 0.5-6 bar
Perm. working pressure: 20 bar
Bursting pressure: >100 bar
Important:
All pressure data refers to overpressures or vacuums relative to atmospheric pressure.
Overpressures have a positive sign, vacuums a negative sign.

Share Link: 