MITSUBISHI <CONTROL / DRIVER IC>
M54125L/P
EARTH LEAKAGE CURRENT DETECTOR
ABSOLUTE MAXIMUM RATINGS (Ta = -20 – 80°C unless otherwise noted)
Symbol
Parameter
Conditions
Ratings
Unit
IS
Supply voltage
Average supply current frequency
per cycle
06
mA
IS(SO)
VILK
VIBL
VOUT
Pd
Topr
Tstg
Supply surge current
ILK input voltage
IBL input voltage
OUT applied voltage
Power dissipation
Operating temperature
Storage temperature
(Note 1)
Pin VB serves as the voltage
reference
When external voltage is applied
0 12
mA
-1.8 +1.8
V
-0.3 6
V
-0.3 4
V
160
mW
-20 80
°C
-55 125
°C
Note 1: IS(SG) current waveform, which is given in the following diagram, shall be one shot or less per minute.
IS(SG)
1µS
40µS
12mA
6mA
0mA
RECOMMENDED OPERATING CONDITIONS (Ta = -20 – 80°C unless otherwise noted)
Symbol
Parameter
VS
Supply voltage
IS
Supply current
When output OUT is OFF
Average power supply current per
cycle
CMM
CWF
CTD
RX
External capacitor MM
External capacitor WF
External capacitor TD
External resistor RX
Handling of unused pins when the abnormal voltage detection function is not used
• Pin RX must be left open
• Pin TD must be shorted to GND
• Pin WF and pin IBL may be left open or shorted to GND
Limits
Unit
Min. Typ. Max.
12
V
5.6 mA
0.22
µF
1
µF
6.8
µF
27
k