DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AEV23024 データシートの表示(PDF) - Panasonic Corporation

部品番号
コンポーネント説明
メーカー
AEV23024 Datasheet PDF : 6 Pages
1 2 3 4 5 6
COMPACT BUT CUT OFF DC
EV-RELAYS POWER CURRENT, POWER
CAPSULE CONTACT RELAY.
150A 2a
60a
150A 1a
30a
FEATURES
• Small size & light weight: size 1/4,
weight 1/2(compared to conventional
contactors)
• No arc space is required: size includ-
ing arc space 1/9 (compared to con-
ventional contactors)
The arc is not exposed to the outside,
therefore, no arc space is not required.
• Safety construction
The arc is not exposed, therefore, the
contactor is explosion proof and intrinsi-
cally safe.
• Quiet: operation noise 1/4 (compared
to conventional contactors).
Along with the above-mentioned miniatur-
ization, the operation noise has been re-
duced to 70dB, and, in addition, the
operation noise remains unchanged
when a current of 1000A or more is inter-
rupted.
• High contact reliability
The contact part is hermetically sealed
with H2 mixed gas, hence the contact re-
sistance remains stable regardless of the
ambient conditions.
• Mounting direction is not specified
The weight of the movable parts is light,
and also the restoring force is large,
hence the contactor is relatively unaffect-
ed by gravity.
• Line-up of indicator Type (150A Type
only)
A line-up of relays with indicator that can
monitor the relay operation.
SPECIFICATIONS
Contact
Type
Arrangement
Rating
Nominal switching capacity
(resistive load)
Short term current
Max. cut-off current
Overload opening/closing rating
Contact voltage drop (Max.)
Nominal operating power
Expected life
Mechanical
(min. operations) Electrical
150A type
1 Form A, 2 Form A
150A 400V DC
300A (10min) (40mm2)
2,500A 300V DC (3 cycles)#1
600A 300V DC (25 cycles)
0.1V (When current (is 150A
per 1) contact set)
35W (Inrush, approx 0.1s)
5W (Stable)
1 Form A: 105
2 Form A: 5 × 104
150A 400V DC 103
L/R q 1ms
60A type
1 Form A
60A 400V DC
120A (15min) (15mm2)
600A 300V DC (5 cycles)
120A 400V DC (50 cycles)
0.1V (When current (is 60A
per 1) contact set)
Max. 5W
30A type
1 Form A
30A 400V DC
60A (5min) (5.5mm2)
120A 400V DC (50 cycles)
0.2V (When current (is 30A
per 1) contact set)
Max. 5W
60A 400V DC 103
L/R q 1ms
105
30A 400V DC 3 × 104
L/R q 1ms
Characteristics
Initial insulation resistance
Initial
breakdown voltage
Between open contacts
Between contact and coil
Operate time (at 20°C) (at nominal voltage)
Reset time (without diode) (at 20°C) (at nominal voltage)
Shock resistance
Functional
Destructive
Vibration resistance
Functional
Destructive
Conditions for operation, transport and storage Ambient temperature
(Not freezing and condensing at low temperature) Humidity
Unit weight
Min. 100 M(at 500 V DC)*1
AC 2,500 Vrms for 1 min.*2
AC 2,500 Vrms for 1 min.*2
Max. 50ms*3
Max. 30ms*4
Min. 196 m/s2 {20 G}*5
Min. 490 m/s2 {50 G}*6
43 m/s2 {4.4 G} 10 to 200Hz*7
43 m/s2 {4.4 G} 10 to 200 Hz*8
–40°C to +80°C –40°F to +176°F*9
5 to 85% R.H.
150 A 1 Form A: 660 g 21.16oz 150 A 2 Form A: 1,100 g 38.80oz
60 A: 330 g 11.64oz 30 A: 310 g 10.93oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 Detection current: 10mA.
*3 Nominal voltage applied to the coil,excluding bounce time.
*4 Nominal voltage applied to the coil.
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10µs.
*6 Half-wave pulse of sine wave: 6 ms.
*7 Detection time: 10 µs.
*8 3 directions, each 4 hours.
*9 Storage: Max.85°C 185°F.
Notes:
Same specifications as the 12 V type.
#1 Condition: Nominal switching 100cycles, each cut off 2,500A
346