Fault-Protected, High-Voltage,
Dual Analog Switches
ELECTRICAL CHARACTERISTICS—Single Supply (continued)
(V+ = +15V, V- = -15V, VINL_ = 0.8V, VINH_ = 2.4V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.) (Note 3)
PARAMETER
POWER SUPPLY
SYMBOL
CONDITIONS
TA
MIN TYP MAX UNITS
Power-Supply Range
V+, V-
C, E, M
0
36
V
V+ Supply Current
GND Supply Current
I+
IGND
All VIN_ = 0 or 5V,
VNO_ or VNC_ = 0
All VIN_ = 0 or 5V,
VNO_ or VNC_ = 0
+25°C
C, E, M
+25°C
C, E, M
165 250
µA
400
165 250
µA
400
Note 2: NC_ and NO_ pins are fault protected (see Electrical Characteristics). With power applied to V+ or V-, signals on NC_ or
NO_ exceeding ±25V (MAX4632) or ±36V (MAX4631/MAX4633) may damage the device. With V+ = V- = 0, signals on NC_
or NO_ exceeding ±40V may damage the device.
Note 3: The algebraic convention is used in this data sheet; the most negative value is shown in the minimum column.
Note 4: RON = RON(MAX) - RON(MIN).
Note 5: Leakage parameters are 100% tested at maximum rated hot temperature and guaranteed by correlation at +25°C.
Note 6: Guaranteed by design.
Note 7: Off-isolation = 20log10 [VCOM_ / (VNC_ or VNO_)], VCOM_ = output, VNC_ or VNO_ = input to off switch.
Note 8: Between any two switches.
Note 9: Leakage testing for single-supply operation is guaranteed by testing with dual supplies.
(TA = +25°C, unless otherwise noted.)
SWITCH ON-RESISTANCE vs. VCOM
(DUAL SUPPLIES)
200
180
160
V+ = +5V
V- = -5V
140
120 V+ = +10V
100 V- = -10V
V+ = +12V
V- = -12V
80
60
40 V+ = +15V
20 V- = -15V
V+ = +20V
V- = -20V
0
-20 -15 -10
-5 0 5
VCOM (V)
10 15 20
Typical Operating Characteristics
ON-RESISTANCE vs. VCOM
AND TEMPERATURE (DUAL SUPPLIES)
120
100
TA = +85°C TA = +125°C
80
60
40
TA = +25°C
20
TA = -40°C
V+ = 15V
V- = -15V
0
-15 -10 -5 0 5
VCOM (V)
TA = -55°C
10 15
500
450
400
350
300
250
200
150
100
50
0
SWITCH ON-RESISTANCE
vs. VCOM (SINGLE SUPPLY)
V+ = +5V
V- = GND
V+ = +8V
V+ = +12V
V+ = +15V
V+ = +20V
V+ = +24V
V+ = +30V
5 10 15 20 25 30
VCOM (V)