Philips Semiconductors
Pulse Pattern Generator for Frame Transfer
CCD (PPGFT)
Objective specification
SAA8103
9 OPERATING MODES
For Full Frame CCD and Frame Transfer CCD there are two modes for data read-out: Shot mode and Preview mode.
Shot mode is used to take an image using an external trigger signal; e.g. camera shutter. Preview mode is used to take
an image continuously with a fixed (preset) integration; e.g. to show an image on the LCD display of a Digital Still Camera
(DSC).
9.1 Full Frame CCD
In the Shot mode, the SAA8103 takes the external input signal TRG, as the trigger signal. After the rising edge of TRG,
the charge reset pulses (CR) are generated for the appropriate period. Integration time is held until the falling edge of
the TRG signal. A drive signal is generated in each VD period but is not issued until the next event of the TRG signal.
In the Preview mode, the SAA8103 generates a drive signal in every frame. The Preview mode it is not influenced by the
TRG signal. The integration time is controlled using the INTTIME command; see Chapter 11, addresses 1 and 2.
The Shot mode and Preview mode for Full Frame CCD is shown in Fig.4.
handbook,Sfuhlloptamgeowdideth
TRG
CR
VD
Data read-out
Preview mode
VD
CR
Data read-out
2001 Oct 22
integration time
integration time
Fig.4 Data read-out of Full Frame CCD.