DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

IS61C6416 データシートの表示(PDF) - Integrated Silicon Solution

部品番号
コンポーネント説明
メーカー
IS61C6416
ISSI
Integrated Silicon Solution ISSI
IS61C6416 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
IS61C6416
ISSI ®
ABSOLUTE MAXIMUM RATINGS(1)
Symbol Parameter
VTERM Terminal Voltage with Respect to GND
TSTG Storage Temperature
PT
Power Dissipation
IOUT DC Output Current (LOW)
Value
–0.5 to +7.0
–65 to +150
1.5
20
Unit
V
°C
W
mA
Note:
1. Stress greater than those listed under ABSO-
LUTE MAXIMUM RATINGS may cause per-
1 manent damage to the device. This is a stress
rating only and functional operation of the
device at these or any other conditions above
those indicated in the operational sections of
this specification is not implied. Exposure to
2 absolute maximum rating conditions for ex-
tended periods may affect reliability.
OPERATING RANGE
Range
Ambient Temperature
Speed
VCC
3
Commercial
0°C to +70°C
-10, -12 5V ± 5%
-15, -20 5V ± 10%
Industrial
–40°C to +85°C
-12 5V ± 5%
-15, -20 5V ± 10%
4
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol Parameter
VOH
Output HIGH Voltage
VOL
Output LOW Voltage
VIH
Input HIGH Voltage
VIL
Input LOW Voltage(1)
ILI
Input Leakage
ILO
Output Leakage
Test Conditions
VCC = Min., IOH = –4.0 mA
IOH = –100 µA
VCC = Min., IOL = 8.0 mA
GND VIN VCC
GND VOUT VCC, Outputs Disabled
Notes:
1. VIL (min.) = –3.0V for pulse width less than 10 ns.
5
Min.
Max.
Unit
2.4
3.95
0.4
V
6
V
2.2 VCC + 0.5 V
–0.5
0.8
–2
2
V7
µA
–2
2
µA
8
POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
Symbol Parameter
ICC
Vcc Dynamic Operating
Supply Current
ISB1
TTL Standby Current
(TTL Inputs)
ISB2
CMOS Standby
Current (CMOS Inputs)
Test Conditions
VCC = Max.,
IOUT = 0 mA, f = MAX
VCC = Max.,
VIN = VIH or VIL
CE VIH , f = max
VCC = Max.,
CE VCC – 0.2V,
VIN VCC – 0.2V, or
VIN 0.2V, f = 0
Com.
Ind.
Com.
Ind.
Com.
Ind.
-10
Min. Max.
— 300
——
— 50
——
— 10
——
-12
Min. Max.
— 280
— 300
— 50
— 55
— 10
— 15
-15
Min. Max.
— 260
— 290
— 50
— 55
— 10
— 15
9
-20
Min. Max. Unit
10 — 235 mA
— 255
— 50 mA
— 55
11
— 10 mA
— 15
12
Note:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
Integrated Silicon Solution, Inc. — 1-800-379-4774
3
SR005-1D
05/24/99

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]