DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HFCT-5305 データシートの表示(PDF) - HP => Agilent Technologies

部品番号
コンポーネント説明
メーカー
HFCT-5305 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
through a 10 load instead of
the normal 50 ECL load.
Regulatory Compliance
See the Regulatory Compliance
Table for the targeted typical
and measured performance for
these transceivers. As the
product design is completed,
full characterization testing
will be done to determine the
actual performance of the final
design.
The overall equipment design will
determine the level it is able to be
certified to. These transceiver
performance targets are offered
as a figure of merit to assist the
designer in considering their use
in equipment designs.
Electrostatic Discharge (ESD)
There are two design cases in
which immunity to ESD damage
is important.
The first case is during handling
of the transceiver prior to mount-
ing it on the circuit board. It is
important to use normal ESD
handling precautions for ESD
sensitive devices. These pre-
cautions include using grounded
wrist straps, work benches, and
floor mats in ESD controlled
areas.
The targeted performance has
been shown to provide adequate
performance typical industry
production environments.
The second case to consider is
static discharges to the exterior
of the equipment chassis
containing the transceiver parts.
To the extent that the duplex SC
connector is exposed to the
outside of the equipment chassis
it may be subject to whatever
system level ESD test criteria that
the equipment is intended to
meet. The targeted performance
is more robust than typical
industry equipment practices
today.
Electromagnetic Interference
(EMI)
Most equipment designs utilizing
these high speed transceivers
from Hewlett-Packard will be
required to meet the require-
ments of FCC in the United
States, CENELEC EN55022
(CISPR 22) in Europe and VCCI
in Japan.
These transceivers, with their
shielded design, are targeted to
perform to the limits listed to
assist the designer in the
management of the overall
equipment EMI performance.
Immunity
Equipment utilizing these
transceivers will be subject to
radio-frequency electromagnetic
fields in some environments.
Regulatory Compliance
Feature
Test Method
Targeted Performance
Electrostatic Discharge MIL-STD-883C
(ESD) to the
Method 3015.4
Electrical Pins
Class 1 (>500 V)
Electrostatic Discharge Variation of IEC 801-2
(ESD) to the
Duplex SC Receptacle
Products of this type will typically withstand at
least 25 kV without damage when the Duplex
SC Connector Receptacle is contacted by a
Human Body Model probe.
Electromagnetic
Interference (EMI)
FCC Class A
CENELEC EN55022 Class A
(CISPR 22A)
VCCI Class I
Typically provide a TBD dB margin to the noted
standard limits when tested at a certified test
range with the transceiver mounted to a circuit
card without a chassis enclosure.
Immunity
Variation of IEC 801-3
Typically show no measurable effect from a
3 V/m field swept from 10 to 450 MHz applied
to the transceiver without a chassis enclosure.
Eye Safety
FDA CDRH 21-CFR 1040 Class Compliant per Hewlett-Packard Testing for all
1 IEC 825 Issue 1 1993:
three requirements under normal operating
11 Class
conditions. Fault condition testing pending
1 CENELEC EN60825 Class 1 completion of product development.