Technical Data Sheet
MITSUBISHI
PRELIMINARY
MITSUBISHI CMOS Image Sensor
M64285FP
11. Description of Functions
11.1. State Diagram
Set STOP=1
Standby
• Register setting
• Reset State
Assert START
(MD3=0)
Image output over
Assert START
(MD3=1)
Assert START
Continuous Mode
image capture
& output
Snapshot Mode
image capture
& output
The state diagram of M64285FP is shown above. The sequence to control M64285FP is
explained below.
(1) Reset all the registers and counters.
RESET is set to "L" (asynchronous to CLK). Reset state is in the Standby state.
(2) Set the contents of the registers.
There are 16 sets of registers, consisting of 4 bits each. The input data is composed of 8
bits. The leading 4 bits are for address and the following 4 bits are for data. The input
data is latched at the rising edge of SCLK. When LOAD goes "H", the contents of the
register become fixed at the rising edge of CLK.
(3) Start image capture.
After the contents of all the registers are fixed, START is asserted in synchronous with
the rising edge of CLK. Then the control counters are reset to the initial value specified
by the registers, and the image capture sequence starts. After the accumulation time
defined by the registers 4 ~ 7, the analog image signals are outputted serially. The STRB
pulse is outputted in synchronous with the above. The number of active data on one
frame is 1024 for the 2D image, 64 for the projection image, and 1 for the pixel average
data; the number of data outputted in each modes is fixed by the combination of the
above. When this chip finishes outputting the defined number of data, in the snapshot
modes (MD3=1), it automatically falls into the Standby state. In the continuous modes
(MD3=0), once the image capture sequence starts, this chip carries on outputting the
image data, unless START is asserted again or STOP bit is set to "H" to force the chip
into the Standby state.
The contents of the registers can be changed in the Standby state. When START is asserted
in the standby state or in the continuous image capture sequence, the control counters are,
again, reset to the initial value specified by the registers, and the image capture sequence
starts. If the register contents are changed before asserting START, M64285FP outputs the
data in a different mode. In the continuous output modes, register No. 2 including the STOP
bit is the only register that is allowed to be set.
( 7 / 26 )
Specifications and information herein are subject to change without notice.
02 / 05 / 01
Ver. 2.2E_01