M64898GP
Method of Setting Data
The programmable divider ratio uses 15 bits. Setting up the band switching output uses 4 bits.
The test mode data uses 8 bits. The total bits used are 27 bits. Data is read in when the enable signal is “H” and the
clock signal falls.
The band switching data is read in at the 4th pulse of the clock signal. The programmable counter data is read into the
latch by the fall of the enable signal after the 18th pulse of the clock signal or the fall of the 19th pulse of the clock
signal. When the enable signal goes to “L” before the 18th pulse of the enable signal, only the band SW data is updated
and other data is ignored.
Automatic judgment facility comes being it, and, as for Shift resister, CONT terminal rises by 18/19 bits at the time of
“L”. At the time of data of 18 bits, M9 bit of Programmable divider is done reset of, and it is established in reference
frequency divider ratio is established 1/512.
At the time of 19 bits, reference frequency divider ratio is established in 1/1024.
When reference frequency divider ratio was established in 1/640 by 19 bits at the time if “opening” CONT terminal,
and it became “L” before 19 pulses enable signal, only band SW data are renewed, and other data are ignored.
1. Transfer of the 18th bit data (CONT terminal is “L”)
Data is latched by the fall of the enable signal after the 18th clock signal. At this time, the divider of the 1/512 of
the reference frequency is used.
ENA
DATA
BS4 BS3 BS2 BS1 28 27 26 25 24 23 22 21 20 24 23 22 21 20
M8 M7 M6 M5 M4 M3 M2 M1 M0 S4 S3 S2 S1 S0
CLK
Band Switch
Data
M Counter Divider
Ratio Setting
Read Into Latch
S Counter Divider
Ratio Setting
Read Into Latch
2. Transfer of the 19th bit data (CONT terminal is “L” or “open”)
The data is latched at the 19th pulse of the clock signal.
Reference frequency divider ratio is established in 1/1024 in case of “L” CONT terminal at this time.
Reference frequency divider ratio is established in 1/640 in case of “opening” CONT terminal.
Invalid the clock signal after 19th pulse.
Note: When CONT terminal is “L”, to change reference frequency, set up as ENA in “L” after 19th pulse of clock
signal by all means.
ENA
DATA
BS4 BS3 BS2 BS1 29 28 27 26 25 24 23 22 21 20 24 23 22 21 20
M9 M8 M7 M6 M5 M4 M3 M2 M1 M0 S4 S3 S2 S1 S0
CLK
Band Switch
Data
Read Into Latch
M Counter Divider
Ratio Setting
S Counter Divider
Ratio Setting
Read Into Latch
Rev.2.00 Jun 14, 2006 page 8 of 13