DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX15020 データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX15020 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MAX15020
2A, 40V Step-Down DC-DC Converter with
Dynamic Output-Voltage Programming
VIN
7.5V TO 40V
C1
560µF
R1
97.5k
R2
4.02k
PWM
INPUT
R3
10kW
0
C3
0.1µF
D2
IN
ON/OFF
DVREG
BST
LX
R5
C10
10
1µF
REG
MAX15020
C2
1µF
FB
C9
0.1µF
REFIN
COMP
SS REFOUT SYNC GND FSEL PGND EP
C8
0.22µF
C5
0.1µF
C4
1µF L1
22µH
D1
C13
330pF
R6
10k
C11
0.027µF
C12
0.1µF
R9
15.8k
VOUT
R7
10k
C7
0.1µF
R8
340
C6
560µF
Figure 2. Typical Application Circuit
Detailed Description
The MAX15020 voltage-mode step-down converter
contains an internal 0.2Ω power MOSFET switch. The
MAX15020 input voltage range is 7.5V to 40V. The internal
low RDS(ON) switch allows for up to 2A of output current.
The external compensation, voltage feedforward, and
automatically adjustable maximum ramp amplitude simpli-
fy the loop compensation design allowing for a variety of L
and C filter components. In shutdown, the supply current is
typically 6μA. The output voltage is dynamically adjustable
from 0.5V to 36V. Additional features include an externally
programmable UVLO through the ON/OFF pin, a program-
mable softstart, cycle-by-cycle current limit, hiccup-mode
output short-circuit protection, and thermal shutdown.
Internal Linear Regulator (REG)
REG is the output terminal of the 8V LDO powered from
IN and provides power to the IC. Connect REG externally
to DVREG to provide power for the internal digital circuitry.
Place a 1μF ceramic bypass capacitor, C2, next to the
IC from REG to GND. During normal operation, REG is
intended for powering up only the internal circuitry and
should not be used to supply power to the external loads.
UVLO/ON/OFF Threshold
The MAX15020 provides a fixed 7V UVLO function which
monitors the input voltage (VIN). The device is held off until
VIN rises above the UVLO threshold.
ON/OFF provides additional turn-on/turn-off control.
Program the ON/OFF threshold by connecting a resis-
tive divider from IN to ON/OFF to GND. The device turns
on when VON/OFF rises above the ON/OFF threshold
(1.225V), given that VIN has risen above the UVLO
threshold.
Driving ON/OFF to ground places the IC in shutdown.
When in shutdown the internal power MOSFET turns off,
all internal circuitry shuts down, and the quiescent supply
current reduces to 6μA (typ.). Connect an RC network
from ON/OFF to GND to set a turn-on delay that can be
used to sequence the output voltages of multiple devices.
www.maximintegrated.com
Maxim Integrated 10

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]