MC-458CA721ESA, 458CA721PSA, 458CA721XSA
DC Characteristics (Recommended Operating Conditions unless otherwise noted)
Parameter
Symbol
Test condition
MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1, tRC tRC(MIN.)
/CAS latency = 2 -A80
550 mA 1
-A10
/CAS latency = 3 -A80
550
-A10
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
5 mA
power down mode
ICC2PS CKE VIL(MAX.), tCK =
5
Precharge standby current in
non power down mode
ICC2N
CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during 30 ns.
100 mA
ICC2NS CKE VIH(MIN.), tCK = , Input signals are stable.
40
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
25 mA
power down mode
ICC3PS CKE VIL(MAX.), tCK =
20
Active standby current in
non power down mode
ICC3N
CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during 30 ns.
150 mA
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
100
Operating current
ICC4 tCK tCK(MIN.), IO = 0 mA
/CAS latency = 2 -A80
725 mA 2
(Burst mode)
-A10
550
/CAS latency = 3 -A80
875
-A10
700
CBR (Auto) refresh current
ICC5
tRC tRC(MIN.)
/CAS latency = 2 -A80
1,150 mA 3
-A10
/CAS latency = 3 -A80
1,150
-A10
Self refresh current
ICC6 CKE 0.2 V
10 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
– 5 +5 µA
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
–1.5 +1.5 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK(MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK(MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK(MIN.).
6
Data Sheet E0067N10

Share Link: 