DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MPX5700 データシートの表示(PDF) - Motorola => Freescale

部品番号
コンポーネント説明
メーカー
MPX5700 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
MPX5700 SERIES
PRESSURE (P1)/VACUUM (P2) SIDE IDENTIFICATION TABLE
Motorola designates the two sides of the pressure sensor
as the Pressure (P1) side and the Vacuum (P2) side. The
Pressure (P1) side is the side containing fluoro silicone gel
which protects the die from harsh media. The Motorola MPX
pressure sensor is designed to operate with positive differen-
tial pressure applied, P1 > P2.
The Pressure (P1) side may be identified by using the table
below:
Part Number
MPX5700D
MPX5700DP
MPX5700GP
MPX5700GS
MPX5700GSX
Case Type
867–08C
867C–05
867B–04
867E–03
867F–03
Pressure (P1)
Side Identifier
Stainless Steel Cap
Side with Part Marking
Side with Port Attached
Side with Port Attached
Side with Port Attached
ORDERING INFORMATION
The MPX5700 pressure sensor is available in differential and gauge configurations. Devices are available in the basic ele-
ment package or with pressure port fittings that provide printed circuit board mounting ease and barbed hose pressure connec-
tions.
MPX Series
Device Type
Options
Case Type
Order Number
Device Marking
Basic Element
Differential
867–08C
MPX5700D
MPX5700D
Ported Elements
Differential Dual Ports
867C–05
MPX5700DP
MPX5700DP
Gauge
867B–04
MPX5700GP
MPX5700GP
Gauge, Axial
867E–03
MPX5700GS
MPX5700D
Gauge, Axial PC Mount
867F–03
MPX5700GSX
MPX5700D
4
Motorola Sensor Device Data

Share Link: 