MX29F200T/B
TABLE1. SOFTWARE COMMAND DEFINITIONS
Command
Reset
Read
Read Silicon ID
Sector Protect
Verify
First Bus
Bus Cycle
Cycle Addr Data
1
XXXH F0H
1
RA RD
Word 4
555H AAH
Byte 4
AAAH AAH
Word 4
555H AAH
Byte 4
AAAH AAH
Porgram
Word 4
Byte 4
Chip Erase
Word 6
Byte 6
Sector Erase
Word 6
Byte 6
Sector Erase Suspend
1
Sector Erase Resume
1
Unlock for sector
6
protect/unprotect
555H AAH
AAAH AAH
555H AAH
AAAH AAH
555H AAH
AAAH AAH
XXXH B0H
XXXH 30H
555H AAH
Second Bus Third Bus Fourth Bus
Cycle
Cycle
Cycle
Addr Data Addr Data Addr Data
Fifth Bus
Cycle
Addr Data
2AAH 55H 555H 90H ADI DDI
555H 55H AAAH 90H ADI DDI
2AAH 55H 555H 90H (SA) XX00H
X02H XX01H
555H 55H AAAH 90H (SA) 00
X04H 01
2AAH 55H 555H A0H PA
PD
555H 55H AAAH A0H PA
PD
2AAH 55H 555H 80H 555H AAH 2AAH 55H
555H 55H AAAH 80H AAAH AAH 555H 55H
2AAH 55H 555H 80H 555H AAH 2AAH 55H
555H 55H AAAH 80H AAAH AAH 555H 55H
2AAH 55H 555H 80H 555H AAH 2AAH 55H
Sixth Bus
Cycle
Addr Data
555H 10H
AAAH 10H
SA 30H
SA 30H
555H 20H
NOTE:
1. ADI = Address of Device identifier; A1=0, A0 =0 for manufacture code, A1=0, A0 =1 for device code.(Refer to Table 3)
DDI = Data of Device identifier : C2H for manufacture code,51H/57H(x8) and 2251H/2257H(x16) for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read.
RD=Data to be read at location RA.
2. PA = Address of memory location to be programmed.
PD = Data to be programmed at location PA.
SA = Address to the sector to be erased.
3. The system should generate the following address patterns: 555H or 2AAH to Address A0~A10.
Address bit A11~A16=X=Don't care for all address commands except for Program Address (PA) and Sector Address (SA).
Write Sequence may be initiated with A11~A16 in either state.
4. For Sector Protection Verify Operation : If read out data is 01H, it means the sector has been protected. If read out data is
00H, it means the sector is still not being protected.
COMMAND DEFINITIONS
Device operations are selected by writing specific ad-
dress and data sequences into the command register.
Writing incorrect address and data values or writing
them in the improper sequence will reset the device to
the read mode. Table 1 defines the valid register
command sequences. Note that the Erase Suspend
(B0H) and Erase Resume (30H) commands are valid
only while the Sector Erase operation is in progress.
Either of the two reset command sequences will reset
the device(when applicable).
P/N:PM0549
REV. 1.3 , DEC. 24, 2001
6