Technical Specification
Over-Temperature Shutdown: A temperature sensor on the
converter senses the average temperature of the module. The ther-
mal shutdown circuit is designed to turn the converter off when the
temperature at the sensed location reaches the Over-Temperature
Shutdown value. It will allow the converter to turn on again when
the temperature of the sensed location falls by the amount of the
Over-Temperature Shutdown Restart Hysteresis value.
Vin
UVLO
On/Off
(N logic)
OFF
ON
t0 t1
t2 t3
t
Vout
12V
200 ms
Time
12 ms
208 ms
Figure E: Power Up/Down Diagram (not to scale) showing
Start-Up Inhibit Period.
Input: 36-75 V
Output: 12 V
Current: 28 A
Package: Quarter-brick
APPLICATION CONSIDERATIONS
Start-Up Inhibit Period: Figure E details the Start-Up Inhibit
Period for the BusQor modulewhen Vin is applied with the On/
Off pin asserted (enabled). Before time t1, when the input voltage
is below the UVL threshold, the unit is disabled by the Input Under-
Voltage Lockout feature. When the input voltage rises above the
UVL threshold, the Input Under-Voltage Lockout is released, and a
typical Startup Inhibit Period of 8 ms from a Vin start-up. Once
the module recognizes it should be on it waits an additional 4 ms
before it starts. When starting from an on/off event the module
has an inhibit time of 200 ms like our standard products. The
output builds up to 90% or higher of the nominal voltage and
stabilizes to its nominal output voltage in a total time of 8 ms
typical. The the module has a Vout rise time of 4 ms typically.
At time t2, when the On/Off pin is de-asserted (disabled), the
BusQor module stops switching immediately. Fall time from 12 V to 0
V is dependent on output capacitance load current, and any parasitic
trace inductance in the output load circuit.
At time t3, when the On/Off pin is re-asserted (enabled), the
BusQor module output begins to build up after the inhibit period
of 200 ms typical.
Refer to the Control Features section of the data sheet for details on
enabling and disabling methods for N and P logic type modules.