TRU050, VCXO Based PLL
Performance Characteristics
Table 1. Electrical Performance
Parameter
Symbol Min
Typical Maximum
Units
Output Frequency (ordering option)
Out 1, 5V option
1.000
65.636
MHz
Out 1, 3.3V option
Supply Voltage 1
+5
1.000
VDD
4.5
51.840
5.0
5.5
MHz
V
+3.3
3.0
3.3
3.6
V
Supply Current
Output Logic Levels
Output Logic High2
Output Logic Low2
Output Transition Times
Rise Time2
Fall Time2
Input Logic Levels
Output Logic High2
Output Logic Low2
Loss of Signal Indication
Output Logic High2
Output Logic Low2
Nominal Frequency on Loss of Signal
IDD
VOH
2.5
VOL
tR
tF
VIH
2.0
VIL
VOH
2.5
VOL
65
mA
V
0.5
V
5
ns
5
ns
V
0.5
V
V
0.5
V
Output 1
Output 2
Symmetry or Duty Cycle3
±75
ppm
±75
ppm
Out 1
SYM1
40/60
%
Out 2
SYM2
45/55
%
RCLK
RCLK
40/60
%
Absolute Pull Range, ordering option
over operating temp, aging, power supply
variations
APR
±50
±80
±100
ppm
Test Conditions for APR (+5V option)
VC
0.5
4.5
V
Test Conditions for APR (+3.3V option)
VC
0.3
3.0
V
Gain Transfer
Positive
Phase Detector Gain
+5V option
0.53
rad/V
+3.3V Option
0.35
rad/V
Operating temperature, ordering option
0/70 or –40/85
°C
Control Voltage Leakage Current
IVCXO
±1
uA
1. A good quality 0.01uF in parrallel with a 0.1 uf capacitor should be located as close to pin 16 to ground as possible.
2. Figure 1 defines these parameters. Figure 2 illustrates the equivalent five-gate TTL load and operating conditions under which these parameters are
tested and specified. Loads greater than 15 pF will adversely effect rise/fall time and duty cycle.
3. Symmetry is defined as (ON TIME/PERIOD with Vs=-1.4 V for both 5V and 3.3V operation.
80%
1.4V
20%
TR
TF
On Time
Period
ID D
VDD + .1μF .01μF
-
16
1
IC
VC
+
-
650Ω
3
15pF
1.8k
Figure 2. Output Waveform
Figure 3. OUT1, OUT2, RDATA and RCLK
Test Conditions (25±5°C)
Vectron International, 267 Lowell Rd, Hudson NH 03051-4916
Page 2 of 15
Tel: 1-88-VECTRON-1 Web: www.vectron.com
Rev: 12Aug2009

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]