TRU050, VCXO Based PLL
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can permanently damage the device. Functional
operation is not implied at these or any other conditions in excess of conditions represented in the operational
sections of this data sheet. Exposure to absolute maximum ratings for extended periods may adversely affect
device reliability.
Table 2. Absolute Maximum Ratings
Parameter
Symbol
Power Supply
Storage Temperature
VDD
Tstorage
Soldering Temperature/Duration
Clock and Data Input Range
TPEAK / tP
CLKIN, DATAIN
Ratings
7
-55/125
260 / 40
Gnd-0.5 to VDD +0.5
Unit
Vdc
°C
°C/sec
V
Reliability
The TRU050 is capable of meeting the following qualification tests.
Table 3. Environmental Compliance
Parameter
Mechanical Shock
Mechanical Vibration
Solderability
Gross and Fine Leak
Resistance to Solvents
Conditions
MIL-STD-883, Method 2002
MIL-STD-883, Method 2007
MIL-STD-883, Method 2003
MIL-STD-883, Method 1014, 100% Tested
MIL-STD-883, Method 2016
Handling Precautions
Although ESD protection circuitry has been designed into the the TRU050, proper precautions should be
taken when handling and mounting. VI employs a human body model and a charged-device model (CDM) for
ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on the circuit
parameters used to define the model.
Table 4. ESD Ratings
Model
Human Body Model
Charged Device Model
Minimum
1500V
1000V
MIL-STD 3015
JESD 22-C101