M50FW002
Figure 8. AC Measurement I/O Waveform (A/A Mux Interface)
3V
1.5V
0V
AI01417
Table 17. AC Measurement Conditions (A/A Mux Interface)
Symbol
Parameter
CL
Load Capacitance
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Reference Voltages
Table 18. Device Impedance
Symbol
Parameter 1
CIN
Input Capacitance 2
CCLK
Clock Capacitance 2
LPIN
Recommended Pin
Inductance 3
Note: 1. TA=25°C, f=1 MHz
2. Sampled only, not 100% tested
3. See PCI Specification
Test Condition
VIN = 0V
VIN = 0V
Min.
Max.
30
10
0 to 3
1.5
Min
Max
13
3
12
20
Unit
pF
ns
V
V
Unit
pF
pF
nH