DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M80C286 データシートの表示(PDF) - Intel

部品番号
コンポーネント説明
メーカー
M80C286 Datasheet PDF : 60 Pages
First Prev 51 52 53 54 55 56 57 58 59 60
M80C286
The following comments describe possible excep-
tions side effects and allowed usage for instruc-
tions in both operating modes of the M80C286
REAL ADDRESS MODE ONLY
1 This is a protected mode instruction Attempted
execution in real address mode will result in an
undefined opcode exception (6)
2 A segment overrun exception (13) will occur if a
word operand reference at offset FFFF(H) is at-
tempted
3 This instruction may be executed in real address
mode to initialize the CPU for protected mode
4 The IOPL and NT fields will remain 0
5 Processor extension segment overrun interrupt
(9) will occur if the operand exceeds the seg-
ment limit
EITHER MODE
6 An exception may occur depending on the value
of the operand
7 LOCK is automatically asserted regardless of the
presence or absence of the LOCK instruction
prefix
8 LOCK does not remain active between all oper-
and transfers
PROTECTED VIRTUAL ADDRESS MODE ONLY
9 A general protection exception (13) will occur if
the memory operand cannot be used due to ei-
ther a segment limit or access rights violation If
a stack segment limit is violated a stack seg-
ment overrun exception (12) occurs
10 For segment load operations the CPL RPL and
DPL must agree with privilege rules to avoid an
exception The segment must be present to
avoid a not-present exception (11) If the SS reg-
ister is the destination and a segment not-pres-
ent violation occurs a stack exception (12) oc-
curs
11 All segment descriptor accesses in the GDT or
LDT made by this instruction will automatically
assert LOCK to maintain descriptor integrity in
multiprocessor systems
12 JMP CALL INT RET IRET instructions refer-
ring to another code segment will cause a gener-
al protection exception (13) if any privilege rule is
violated
13 A general protection exception (13) occurs if
CPL i 0
14 A general protection exception (13) occurs if
CPL l IOPL
15 The IF field of the flag word is not updated if CPL
l IOPL The IOPL field is updated only if
CPL e 0
16 Any violation of privilege rules as applied to the
selector operand do not cause a protection ex-
ception rather the instruction does not return a
result and the zero flag is cleared
17 If the starting address of the memory operand
violates a segment limit or an invalid access is
attempted a general protection exception (13)
will occur before the ESC instruction is execut-
ed A stack segment overrun exception (12) will
occur if the stack limit is violated by the oper-
and’s starting address If a segment limit is vio-
lated during an attempted data transfer then a
processor extension segment overrun exception
(9) occurs
18 The destination of an INT JMP CALL RET or
IRET instruction must be in the defined limit of a
code segment or a general protection exception
(13) will occur
51

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]