MITSUBISHI <INTELLIGENT POWER MODULES>
PM75CSD060
FLAT-BASE TYPE
INSULATED PACKAGE
CONTROL PART
Symbol
Parameter
ID
Vth(ON)
Vth(OFF)
Circuit Current
Input ON Threshold Voltage
Input OFF Threshold Voltage
OC
Over Current Trip Level
Test Condition
VD = 15V, VCIN = 15V
VN1-VNC
VXP1-VXPC
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN VN WN-VNC
Tj = 20°C
VD = 15V
(Fig. 5,6) Tj = 25°C
Tj = 125°C
Limits
Min.
Typ.
Max. Unit
40
55
mA
13
18
1.2
1.5
1.8
V
1.7
2.0
2.3
380
192
226
320
A
115
SC
Short Circuit Trip Level
20Tj 125°C, VD = 15V
(Fig. 5,6)
241
A
toff(OC)
OT
OTr
UV
UVr
IFO(H)
IFO(L)
tFO
Over Current Delay Time
Over Temperature Protection
Supply Circuit Under-Voltage
Protection
VD = 15V
Base-plate
Temperature detection, VD = 15V
20 Tj 125°C
Fault Output Current
VD = 15V, VCIN = 15V
Minimum Fault Output Pulse VD = 15V
Width
(Fig. 5,6)
10
µs
Trip level
Reset level
111
118
125
°C
100
Trip level
Reset level
11.5
12.0 12.5
V
12.5
(Note-3)
0.01
mA
10
15
(Note-3) 1.0
1.8
ms
(Note-3) Fault output is given only when the internal OC, SC, OT & UV protection.
Fault output of OC, SC and UV protection operate by upper and lower arms.
Fault output of OT protection operate by lower arm.
Fault output of OC, SC protection given pulse.
Fault output of OT, UV protection given pulse while over level.
MECHANICAL RATINGS AND CHARACTERISTICS
Symbol
Parameter
Mounting torque
Mounting torque
Weight
Main terminal
Mounting part
Test Condition
Limits
Min.
Typ.
Unit
Max.
screw : M5
2.5
3.0
3.5 N m
screw : M5
2.5
3.0
3.5 N m
560
g
RECOMMENDED CONDITIONS FOR USE
Symbol
Parameter
VCC
Supply Voltage
VD
Control Supply Voltage
VCIN(ON) Input ON Voltage
VCIN(OFF) Input OFF Voltage
fPWM
PWM Input Frequency
tdead
Arm Shoot-through
Blocking Time
Test Condition
Recommended value
Unit
Applied across P-N terminals
400
V
Applied between : VUP1-VUPC, VVP1-VVPC
VWP1-VWPC, VN1-VNC
(Note-4)
15 ± 1.5
V
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN VN WN-VNC
0.8
V
4.0
Using Application Circuit input signal of IPM, 3φ
sinusoidal PWM VVVF inverter
(Fig. 8)
20
kHz
For IPMs each input signals
(Fig. 7)
2.5
µs
(Note-4) Allowable Ripple rating of Control Voltage : dv/dt ≤ ±5V/µs, 2Vp-p