Production Data
WM8781
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are stress ratings only. Permanent damage to the device may be caused by continuously operating
at or beyond these limits. Device functional operating limits and guaranteed performance specifications are given under
Electrical Characteristics at the test conditions specified.
ESD Sensitive Device. This device is manufactured on a CMOS process. It is therefore generically susceptible
to damage from excessive static voltages. Proper ESD precautions must be taken during handling and storage
of this device.
Wolfson tests its package types according to IPC/JEDEC J-STD-020B for Moisture Sensitivity to determine acceptable storage
conditions prior to surface mount assembly. These levels are:
MSL1 = unlimited floor life at <30C / 85% Relative Humidity. Not normally stored in moisture barrier bag.
MSL2 = out of bag storage for 1 year at <30C / 60% Relative Humidity. Supplied in moisture barrier bag.
MSL3 = out of bag storage for 168 hours at <30C / 60% Relative Humidity. Supplied in moisture barrier bag.
The Moisture Sensitivity Level for each package type is specified in Ordering Information.
CONDITION
Digital supply voltage
Analogue supply voltage
Voltage range digital inputs
Voltage range analogue inputs
Ambient temperature (supplies applied)
Storage temperature after soldering
Pb free package body temperature (reflow 10 seconds)
Package body temperature (soldering 2 minutes)
Notes
1. Analogue and digital grounds must always be within 0.3V of each other.
MIN
-0.3V
-0.3V
DGND -0.3V
AGND -0.3V
-55oC
-65C
MAX
+4.5V
+7V
DVDD + 0.3V
AVDD +0.3V
+125oC
+150C
+260oC
+183oC
THERMAL PERFORMANCE
PARAMETER
SYMBOL
TEST CONDITIONS MIN
TYP
MAX
SSOP-20 package
Thermal resistance – junction to
ambient
RθJA
81
See note 1
Notes:
1. Figure given for package mounted on 4-layer FR4 according to JESD51-7. (No forced air flow is assumed).
2. Thermal performance figures are estimated.
UNIT
°C/W
RECOMMENDED OPERATING CONDITIONS
PARAMETER
SYMBOL
TEST CONDITIONS
Digital supply range
DVDD
Analogue supply range
AVDD
Ground
DGND,AGND
Operating temperature range
TA
Notes
1. Digital supply DVDD must never be more than 0.3V greater than AVDD.
MIN
2.7
2.7
-25C
TYP
MAX
3.6
5.5
0
+85C
UNIT
V
V
V
V
w
PD, January 2012, Rev 4.5