6 | C-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme
C
1
Series
A
2
Actuator
3
3
Poles
1 SERIES
C
B
4
Circuit
0
5
Aux/Alarm
Switch
10
6
Frequency
& Delay
2 ACTUATOR 1
A Handle, one per pole
B Handle, one per multipole unit
S Mid-Trip Handle, one per pole
T Mid-Trip Handle, one per pole & Alarm Switch
3 POLES 2
1 One
2 Two
3 Three
4 Four
5 Five
6 Six
4 CIRCUIT 3
A 3 Switch Only (No Coil)
B Series Trip (Current)
C Series Trip (Voltage)
D 4 Shunt Trip (Current)
E 4 Shunt Trip (Voltage)
F 4 Relay Trip (Current)
G 4 Relay Trip (Voltage)
H 4,5 Dual Coil with Shunt Trip
Voltage Coil
K 4,5 Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY / ALARM SWITCH
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
03 3 DC 50/60Hz, Switch Only
10 7 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 7 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
42 8 50/60Hz Short, Hi-Inrush
44 8 50/60Hz Medium, Hi-Inrush
46 8 50/60Hz Long, Hi-Inrush
52 8 DC Short, Hi-Inrush
54 8 DC Medium, Hi-Inrush
56 DC Long, Hi-Inrush
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles
5 pole - three handles at center poles 6 pole - four handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available
with circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip
of the breaker. Available with circuit codes B & C.
2 Standard multipole units have all poles identical except when specifying auxiliary
switch and/or mixed poles. 4 pole max with VDE. 5th pole available as Series Trip with
Voltage Coil only.
3 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to
30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.
4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit
Codes D, F, H & K available up to 50 amps maximum Current Rating.
5 Consult factory for available Dual Coil options, as special catalog number is
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip
instantaneously and are rated for intermittent duty only.
6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
8 Available with Circuit Codes B & D only, and up to 50 amps maximum.
9 Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100
are available up to two poles maximum.
10 Terminal Code 1 available to 60 amps maximum.
11 Terminal Codes 2, 4, 5 and C available to 50 amps maximum.
12 Terminal Codes 3, 6 & 9 available to 100 amps maximum.
13 Terminal Code 7 available to 25 amps maximum.
14 Terminal Code A available to 100 amps maximum.
15 Terminal Codes 7, 9 & C are not VDE approved.
16 No marking available. Consult factory. VDE/TUV Approval requires dual
(I-O, ON-OFF) or I-O markings on all handles.
17 Single pole only.
18 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only
and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or
to be used in applications with a motor.
450
7
Current Rating
1
8
Terminal
2
9
Actuator
Color
1
10
Mounting
Bezel/Barrier
C
11
Agency
Approval
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
235 0.350
430 3.000
025 0.025
240 0.400
435 3.500
030 0.030
245 0.450
440 4.000
035 0.035
250 0.500
445 4.500
040 0.040
255 0.550
450 5.000
045 0.045
260 0.600
455 5.500
050 0.050
265 0.650
460 6.000
055 0.055
270 0.700
465 6.500
060 0.060
275 0.750
470 7.000
065 0.065
280 0.800
475 7.500
070 0.070
285 0.850
480 8.000
075 0.075
290 0.900
485 8.500
080 0.080
295 0.950
490 9.000
085 0.085
410 1.000
495 9.500
090 0.090
512 1.250
610 10.000
095 0.095
415 1.500
710 10.500
210 0.100
517 1.750
611 11.000
215 0.150
420 2.000
711 11.500
220 0.200
522 2.250
612 12.000
225 0.250
425 2.500
712 12.500
230 0.300
527 2.750
613 13.000
OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7
CODE AMPERES
A06 6 DC
A32 32 DC
J12 12 AC
A12 12 DC
A48 48 DC
J18 18 AC
A18 18 DC
A65 65 DC
J24 24 AC
A24 24 DC
J06 6 AC
J48 48 AC
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650
660
670
680
685
690
695
810
9
9
9
9
9
9
9
50.000
60.000
70.000
80.000
85.000
90.000
95.000
100.00
J65 65 AC
K20 120 AC
L40 240 AC
8 TERMINAL 15
1 10 Stud 10-32
2 11 Screw 10-32
3 12 Stud 1/4-20
4 11 Stud M5 x 0.8
5 11 Screw M5 x 0.8
6 12
7 13,15
9 15
A 14
C 11,15
Stud M6
0.250 Double Click Connect
7/16” Clip Terminal
Plug-In Stud
5/16” Clip Terminal
9 ACTUATOR COLOR & LEGEND 16
Actuator Color
I-O
ON-OFF
White
A
B
Black
C
D
Red
F
G
Green
H
J
Blue
K
L
Yellow
M
N
Gray
P
Q
Orange
R
S
Black (short handle)17 T
U
Dual
1
2
3
4
5
6
7
8
9
Legend Color
Black
White
White
White
White
Black
Black
Black
White
10 MOUNTING / BARRIERS
MOUNTING STYLE
BARRIERS
Threaded Insert
1 6-32 x 0.195 inches
no
A 6-32 X 0.195 inches
yes
C 18 6-32 X 0.195 inches
yes
2 ISO M3 x 5mm
no
B ISO M3 x 5mm
yes
D 18 ISO M3 x 5mm
yes
Front panel Snap-In, 1.00” [25.4mm] wide bezel
E 17 with Handleguard
no
VOLTAGE
< 300
< 300
≥ 300
< 300
< 300
≥ 300
< 300
11 AGENCY APPROVAL
C UL Recognized, CSA Accepted
D VDE Certified, UL Recognized, CSA Accepted
E TUV Certified, UL Recognized, CSA Accepted
H UL489 Construction: VDE Certified, UL Recognized, CSA Accepted
I UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
CSA Accepted
L UL489 Construction: UL Recognized, CSA Accepted
R UL489 Construction: TUV Certified, UL Recognized, CSA Accepted