DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

EAC-06-332 データシートの表示(PDF) - Unspecified

部品番号
コンポーネント説明
メーカー
EAC-06-332 Datasheet PDF : 3 Pages
1 2 3
Small, common mode EMI/EMC Filters in 150kHz to 1MHz (1-Stage filter)
EAC series
Ordering information
EAC -10 -472 -O
1
2
3
4
1Model Name
R
2Rated Current
3Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code
681
102
222
332
472
Leakage Current
(Input 125/250V 60Hz)
75.5 A/150 A max
0.13mA/0.25mA max
0.25mA/0.5 mA max
0.38mA/0.75mA max
0.5 mA/1.0 mA max
Line to ground
capacitor
(nominal value)
680pF
1000pF
2200pF
3300pF
4700pF
* When the line to ground capacitor code is
different, the attenuation characteristic is
different.
4 Options
D :DIN rail installation type
* The dimensions change when the option is set.
Refer to External view.
The terminal cover is retracted inside the unit
DIN rail installation type is option
Features of EAC series
Small, common mode EMI/EMC Filters in 150kHz to 1MHz(1-Stage filter)
- Single Phase 250 VAC
-Small-size
-Quick and easy push-down terminal
Just connect the wires,push-down and tighten
the screws with a screwdriver
Specifications
No. Items
EAC-03-472 EAC-06-472 EAC-10-472 EAC-16-472 EAC-20-472 EAC-30-472
1 Rated Voltage[V]
AC 1f 250 / DC250
2 Rated Current[A]
3
6
10
16
20
30
3 Test Voltage (Terminal-Mounting Plate)
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 500MW min at room temperature and humidity
5 Leakage current 125/250V 60Hz
0.5mA/1.0mA max
6 DC resistance
180mW max 110mW max 40mW max 20mW max 10mW max 6mW max
7 Safety agency approval temperatures
-25 to +85C (Refer to Derating Curve)
8 Operating temperature
-40 to +85C (Refer to Derating Curve)
9 Operating humidity
20 to 95%RH (Non condensing)
10 Storage temperature/humidity
-40 to +85C/20 to 95%RH (Non condensing)
11 Vibration
10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact
196.1m/s2 (20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
14 Case size (without projection) /Weight
39X30X85 mm [1.54X1.18X3.35 inches] (WXHXD) /170g max (Option : -D refer to external view)
Circuit Diagram
Case
1
LINE
2
3
CY
LOAD
CY
4
CY : Line to ground capacitor : Mounting Plate
EA/ES-1
Derating Curve
100
80
60
40
20
0
-40 -30 -20 40 50 55 60 70 80 90
Ambient Temperature [C]

Share Link: 