MX25L6406E
OPERATING CONDITIONS
At Device Power-Up and Power-Down
AC timing illustrated in Figure 31 and Figure 32 are the supply voltages and the control signals at device power-up
and power-down. If the timing in the figures is ignored, the device will not operate correctly.
During power-up and power down, CS# needs to follow the voltage applied on VCC to keep the device not be se-
lected. The CS# can be driven low when VCC reach Vcc(min.) and wait a period of tVSL.
Figure 31. AC Timing at Device Power-Up
VCC(min)
VCC
GND
CS#
SCLK
SI
tVR
tCHSL
tSLCH
tDVCH
tCHDX
MSB IN
tSHSL
tCHSH
tSHCH
tCLCH
LSB IN
tCHCL
High Impedance
SO
Symbol
tVR
Parameter
VCC Rise Time
Notes
1
Min.
20
Max.
500000
Unit
us/V
Notes :
1. Sampled, not 100% tested.
2. For AC spec tCHSL, tSLCH, tDVCH, tCHDX, tSHSL, tCHSH, tSHCH, tCHCL, tCLCH in the figure, please refer to
"AC CHARACTERISTICS" table.
P/N: PM1577
REV. 1.1, NOV. 17, 2010
41