DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX4945BELA-T データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX4945BELA-T Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
PIN
1, 2
3
4
5
6, 7, 8
Overvoltage-Protection Controllers with
Internal FET
NAME
IN
GP
ACOK
GND
OUT
Pin Description
FUNCTION
Voltage Input. IN powers the charge pump required to turn on the internal switch. When the correct
adapter is plugged in, a 15ms (typ) debouncer prevents false turn-on of the internal switch. Bypass
IN to GND with a 1µF ceramic capacitor as close as possible to the device to enable ±15kV (HBM)
ESD protection on IN.
pFET Gate-Drive Output. GP pulls the external pFET gate down when the input is above ground.
Active-Low Open-Drain Adapter-Voltage Indicator Output. ACOK is driven low after the adapter
voltage is stable between VUVLO and VOVLO for 30ms (typ). Connect a pullup resistor from ACOK to
the logic I/O voltage of the host system.
Ground
Output Voltage. Output of internal switch. Short all pins together for proper operation.
IN
GP
GND
ACOK
+
VOVLO
-
VUVLO
+
-
OUT
CHARGE
PUMP
CHARGE-PUMP
ENABLED
15ms (typ)
DEBOUNCE
TIMER AND
RETRY TIME
RESET
OVERCURRENT
OR
THERMAL
FAULTS
OSCILLATOR
RESET
30ms (typ)
TIMER
MAX4943–MAX4946/MAX4944L/
MAX4945L/MAX4949
Figure 1. Functional Diagram
Detailed Description
The MAX4943–MAX4946/MAX4949 overvoltage-protec-
tion devices feature a low RON internal FET and protect
low-voltage systems against voltage faults up to +28V. If
the input voltage exceeds the overvoltage threshold, the
internal MOSFET is turned off to prevent damage to the
protected components. These devices also drive an
optional external pFET to protect down to -28V. If the
adapter voltage drops below ground, the pFET turns off
to prevent damage to the protected components due to
negative voltage exposure. The internal charge pump’s
15ms (typ) debounce time prevents false turn-on of the
internal switch during startup. An open-drain, active-low
logic output is available to signal that a successful
power-up has occurred.
_______________________________________________________________________________________ 5