VISHAY
data stream. This gap time should have at least same
length as the burst.
• Up to 1400 short bursts per second can be received
continuously.
Some examples for suitable data format are: NEC
Code, Toshiba Micom Format, Sharp Code, RC5
Code, RC6 Code, R-2000 Code, Sony Format
(SIRCS).
When a disturbance signal is applied to the
TSOP17..KA1 it can still receive the data signal. How-
ever the sensitivity is reduced to that level that no
unexpected pulses will occure.
Some examples for such disturbance signals which
are suppressed by the TSOP17..KA1 are:
• DC light (e.g. from tungsten bulb or sunlight)
• Continuous signal at 38 kHz or at any other fre-
quency
• Signals from fluorescent lamps with electronic bal-
last (an example of the signal modulation is in the fig-
ure below).
TSOP17..KA1
Vishay Semiconductors
IR Signal from fluorescent
lamp with low modulation
0
16920
5
10
15
20
Time ( ms )
Figure 14. IR Signal from Fluorescent Lamp with low Modulation