cycles, which adds 40kHz to the initial frequency of the
external soft-start circuit, as shown in Figure 20. Thus,
the initial frequency of the soft-start is given as:
f ISS = (5.2kΩ + 5.2kΩ ) ×100 + 40 (kHz) (3)
Rmin
RSS
It is typical to set the initial frequency of soft-start 2~3
times the resonant frequency (fO) of the resonant
network.
The soft-start time is determined by the RC time
constant as:
TSS = RSS CSS
(4)
fs
f ISS
40kHz
Control loop
take over
Figure 22. Control Pin Configuration for Pulse
Skipping
Remote On / Off: When an auxiliary power supply is
used for standby, the main power stage using FSFR-
series can be shut down by pulling down the control pin
voltage, as shown in Figure 23. R1 and C1 are used to
ensure soft-start when switching resumes.
time
Figure 20. Frequency Sweeping of Soft-start
4. Control Pin: The FSFR-series has a control pin that
can be used for protection, cycle skipping, and remote
on/off. Figure 21 shows the internal block diagram for
control pin.
LVcc
Idelay
CON 2
-
0.6V/0.4V
+
+
5V
OLP
-
LVcc
+
OVP
-
LVcc good
SQ
R -Q
Auto-restart
protection
Stop
switching
Figure 21. Internal Block of Control Pin
Protection: When the control pin voltage exceeds 5V,
protection is triggered. Detailed applications are
described in the protection section.
Pulse Skipping: FSFR-series stops switching when the
control pin voltage drops below 0.4V and resumes
switching when the control pin voltage rises above 0.6V.
To use pulse-skipping, the control pin should be
connected to the opto-coupler collector pin. The
frequency that causes pulse skipping is given as:
SKIP = 5.2k + 4.16k x100(kHz) (5)
R min R max
R1
C1
FPS
Rmin
OP1
Main
Output
Main Off
Aux
Output
OP1
Figure 23. Remote On / Off Circuit
5. Protection Circuits: The FSFR-series has several
self-protective functions, such as Overload Protection
(OLP), Over-Current Protection (OCP), Abnormal Over-
Current Protection (AOCP), Over-Voltage Protection
(OVP), and Thermal Shutdown (TSD). OLP, OCP, and
OVP are auto-restart mode protections, while AOCP and
TSD are latch-mode protections, as shown in Figure 24.
Auto-restart Mode Protection: Once a fault condition is
detected, switching is terminated and the MOSFETs
remain off. When LVcc falls to the LVcc stop voltage of
11V, the protection is reset. The FPS resumes normal
operation when LVcc reaches the start voltage of 14V.