AS5045
Data Sheet
11.3 Non-permanent Programming
It is also possible to re-configure the AS5045 in a non-permanent way by overwriting the OTP register.
This procedure is essentially a “Write Data” sequence (see Figure 10) without a subsequent OTP programming
cycle.
The “Write Data” sequence may be applied at any time during normal operation. This configuration remains set while
the power supply voltage is above the power-on reset level (see 6.6).
See Application Note AN5000-20 for further information.
Figure 10. Programming Access – Write Data (section of Figure 11)
CSn
Prog
tDatain
CCW Z11 Z10 Z9 Z8 Z7 Z6 Z5 Z4 Z3 Z2 Z1
1
8
CLKPROG
tProg enable
tDatain valid
tclk
see text
Zero Position
Technicaaml scoAnGtent Figure 11. Complete Programming Sequence
still valid Z0
PWM
dis
Mag
Comp
EN
PWM
half
EN
16
PW M and status
bit m odes
www.austriamicrosystems.com
Revision 1.7
19 – 33