DC Characteristics (Recommended Operating Conditions unless otherwise noted)
[MC-4516DA726F]
Parameter
Symbol
Test condition
MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1, tRC tRC(MIN.) ,
IO = 0 mA
/CAS latency = 2
/CAS latency = 3
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC2PS CKE VIL(MAX.), tCK =
Precharge standby current in ICC2N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
non power down mode
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH (MIN.), tCK = ,
Input signals are stable.
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC3PS CKE VIL(MAX.), tCK =
Active standby current in
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
non power down mode
Input signals are changed one time during 30 ns.
-A80
-A10
-A80
-A10
1,650 mA 1
1,470
1,740
1,560
268 mA
19
610 mA
108
340 mA
72
700 mA
Operating current
ICC3NS CKE VIH (MIN.), tCK = ,
Input signals are stable.
ICC4 tCK tCK(MIN.) , IO = 0 mA
/CAS latency = 2 -A80
180
1,920 mA 2
(Burst mode)
-A10
1,560
/CAS latency = 3 -A80
2,190
-A10
1,920
CBR (Auto) refresh current ICC5 tRC tRC(MIN.)
/CAS latency = 2 -A80
2,640 mA 3
-A10
2,640
/CAS latency = 3 -A80
2,730
-A10
2,730
Self refresh current
ICC6 CKE 0.2 V
268 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
– 10 + 10 µA
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
– 1.5 + 1.5 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).