DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

NTE1215MC データシートの表示(PDF) - Murata Power Solutions

部品番号
コンポーネント説明
メーカー
NTE1215MC
Murata-ps
Murata Power Solutions Murata-ps
NTE1215MC Datasheet PDF : 6 Pages
1 2 3 4 5 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
TOLERANCE ENVELOPES
3.3V output types.
+9%
+1%
Typical Load Line
+1%
V
NOM
-7%
-7%
All other types.
+10%
+5%
V
NOM
Typical Load Line
+2.5%
-2.5%
-7.5%
-15%
10 25
50
75 100
Output Load Current (%)
10 25
50
75 100
Output Load Current (%)
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
RoHS COMPLIANCE, MSL AND PSL INFORMATION
This series is compatible with RoHS soldering systems and is also backward compatible with Sn/Pb soldering systems.
The NTE series has a process, moisture, and reflow sensitivity classification of MSL1 PSL R7F as defined in J-STD-020
and J-STD-075. This translates to: MSL1 = unlimited floor life, PSL R7F = Peak reflow temperature 245°C with a
limitation on the time above liquidus (217°C) which for this series is 60sec max. The pin termination finish on this product
series is Gold with a plating thickness of 0.05 microns minimum.
For further information please visit www.murata-ps.com/rohs
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
NTE0303MC
NTE0305MC
NTE0309MC
NTE0312MC
NTE0315MC
NTE0503MC
NTE0505MC
NTE0505MEC
Start-up time
μs
437
1359
3435
6590
7625
533
1368
721
NTE0506MC
NTE0509MC
NTE0512MC
NTE0515MC
NTE1205MC
NTE1209MC
NTE1212MC
NTE1215MC
Start-up time
μs
7200
3146
4960
7740
895
2150
3640
7180
Typical Start-Up Wave Form