DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-K54L-060E データシートの表示(PDF) - Broadcom Corporation

部品番号
コンポーネント説明
メーカー
ACPL-K54L-060E
BOARDCOM
Broadcom Corporation BOARDCOM
ACPL-K54L-060E Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ACPL-M50L, ACPL-054L, ACPL-W50L,
ACPL-K54L
Low Power, 1 MBd Digital Optocoupler
Data Sheet
Description
The Broadcom® ACPL-M50L (single-channel in SO-5 footprint),
ACPL-054L (dual-channel in SO-8 footprint), ACPL-W50L
(single-channel in stretched SO-6 footprint), and ACPL-K54L
(dual-channel in stretched SO-8 footprint) are low power,
low-input current, 1 MBd digital optocouplers.
These digital optocouplers use an insulating layer between the
light-emitting diode and an integrated photon detector to
provide electrical insulation between input and output.
Separate connections for the photodiode bias and output
transistor collector increase the speed up to a hundred times
over that of a conventional photo-transistor coupler by
reducing the base-collector capacitance.
The ACPL-M50L/054L/W50L/K54L has an increased common
mode transient immunity of 15 kV/μs minimum at VCM = 1500V
over a temperature range of –40°C to 105°C. The current
transfer ratio (CTR) is 140% typical for ACPL-M50L or 130%
typical for ACPL-054L/W50L/K54L at IF = 3mA. This digital
optocoupler can be used in any TTL/CMOS, TTL/LSTTL, or wide
bandwidth analog applications.
CAUTION
Take normal static precautions in handling and
assembly of this component to prevent damage
and/or degradation that might be induced by
electrostatic discharge (ESD). The components
featured in this data sheet are not to be used in
military or aerospace applications or
environments
Features
Wide supply voltage Vcc: 2.7V to 24V
Low drive current: 3 mA
Open-collector output
TTL compatible
Compact SO-5, SO-8, stretched SO-6, and stretched SO-8
package
15 kV/μs high common-mode rejection at VCM = 1500 V
Guaranteed performance from temperature range: –40°C
to +105°C
Low propagation delay: 1 μs max at 5V
Worldwide safety approval:
UL1577 recognized, 3750 Vrms/1 min for
ACPL-M50L/054L, 5000 Vrms/1 min for ACPL-W50L/K54
CSA Approval
IEC/EN/DIN EN 60747-5-5 Approval for Reinforced
Insulation
Applications
Communications interface
Digital signal isolation
Micro-controller interface
Feedback elements in switching power supplies
Digital isolation for A/D, D/A conversion digital field
Broadcom
-1-

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]