Non-Isolated DC/DC Converters
6 Amps
JWC006 Series
XPiQ inc.
Intelligent Design Quality Product
•
High Efficiency
•
Low Profile
•
Parallelable/Current Sharing
•
300 A/µs Transient Response
•
Single Control Pin
•
Safety Approvals UL, cUL, TÜV
Specification
Input
Input Voltage Range •
Input Current
•
Start-Up Time
•
Remote On/Off
•
Input Reflected
•
Ripple (V)
Input Reflected
•
Ripple (I)
Output
Output Voltage Range •
Output Voltage Adj. •
Line Regulation
•
Load Regulation
•
Output Voltage
•
Accuracy
Ripple & Noise
•
Transient Response •
Overcurrent
•
Protection
Short Circuit
•
Protection
3.3 V (3.0 V to 3.6 V) or
5.0 V (4.5 V to 5.5 V)
5.5 A at 3.3 V, 5.0 A at 5.0 V
<10 ms
Open (logic high) = ON,
Ground (logic low) = OFF
<250 mV pk-pk
<100 mA pk-pk
1.5 V to 3.3 V - See Table
±10%
See Tables
See Tables
See Tables
100 mV pk-pk max for 5.0 V in,
80 mV pk-pk max for 3.3 V in
Max deviation of ±165 mV settling to
within 95% nominal in <50 µs for
3 A step load change
Operates at 7.5 to 10.0 A
Operates in Hiccup mode
General
Efficiency
•
Isolation Voltage
•
Size
•
Weight
•
MTBF
•
Environmental
Operating
•
Temperature
Cooling
•
EMC & Safety
Safety Approvals
•
See Table
Non-isolated
1.756” x 0.500” x 2.480”
5.1 g
1,500 000 hours calculated
to Bellcore
0 °C to +80 °C (See Derating Curve)
Full power to +50 °C
See derating curve
Approved to UL 60950,
IEC 60950 and CSA 60950
•
www.XPiQ.com
PH: 508 429.9883
•
FAX: 800 226.2100
Email: sales@xpiq.com