MAX15112 Evaluation Kit
Evaluates: MAX15112
When no external reference is applied at SS/REFIN, the
device uses the internal 0.6V reference. An external
tracking reference with steady-state value between 0
and VIN - 2.5V can be applied to SS/REFIN. Refer to the
Setting the Soft-Start Time section of the MAX15112 IC
data sheet for a more detailed description. During 1ms
hiccup timeout, the SS/REFIN pin is pulled to GND inter-
nally to discharge the soft-start capacitor. R6 limits the
currents from an externally supplied reference during the
1ms hiccup timeout event.
Setting the Output Voltage
The EV kit can be adjusted from 0.6V up to 0.94 x VIN
(forced PWM) by changing the values of resistors R1 and
R2. To determine the value of the resistor-divider, first
select R2 between 1kI and 20kI. Then use the following
equation to calculate R1:
R1 = R2 [(VOUT/VFB) - 1]
where VFB is equal to the reference voltage at SS/REFIN
and VOUT is the desired output. If no external reference is
applied at SS/REFIN the internal reference is automatically
selected and VFB becomes 0.6V. When regulating for an
output of 0.6V in skip mode, set R1 to 0I and keep R2
connected from FB to GND.
When R1 is changed, compensation components C14,
R1, and C15 must be changed to ensure loop stability
(refer to the Compensation Design Guidelines section in
the MAX15112 IC data sheet).
Regulator Enable (EN)
The device features a regulator enable input. For normal
operation, a shunt should be installed on jumper JU1.
To disable the output, remove the shunt on JU1 and the
EN pin will be pulled to PGND through resistor R4. See
Table 1 for JU1 settings.
Skip-Mode Input (SKIP)
The device offers selectable skip-mode functionality
to reduce current consumption and achieve a higher
efficiency at light loads. To operate in skip mode, install
a shunt on pins 1-2 on jumper JU2. See Table 2 for JU2
settings. Caution: Do not change the setting of the
skip jumper while the device is operating.
Table 1. Regulator Enable (EN) Jumper JU1 Description
SHUNT POSITION
Installed*
Not installed
*Default position.
EN PIN
Connected to IN
Pulled to PGND through R4
Table 2. Skip-Mode Input (SKIP) Jumper JU2 Description
SHUNT POSITION
1-2
2-3*
*Default position.
SKIP PIN
Connected to EN
Connected to PGND
DEVICE OUTPUT
Enabled
Disabled
MODE
Skip-mode operation
Forced-PWM operation