A15
SA0
0
SA1
1
SA2
1
SA3
1
SA4
1
Table 2. Sector Addresses Tables (Am29F100T)
A14
A13
A12
(x8) Address Range (x16) Address Range
X
X
X
00000h-0FFFFh
00000h-07FFFh
0
X
X
10000h-17FFFh
08000h-0BFFFh
1
0
0
18000h-19FFFh
0C000h-0CFFFh
1
0
1
1A000h-1BFFFh
0D000h-0DFFFh
1
1
X
1C000h-1FFFFh
0E000h-0FFFFh
A15
SA0
0
SA1
0
SA2
0
SA3
0
SA4
1
Table 3. Sector Addresses Tables (Am29F100B)
A14
A13
A12
(x8) Address Range (x16) Address Range
0
0
X
00000h-03FFFh
00000h-01FFFh
0
1
0
04000h-05FFFh
02000h-02FFFh
0
1
1
06000h-07FFFh
03000h-03FFFh
1
X
X
08000h-0FFFFh
04000h-07FFFh
X
X
X
10000h-1FFFFh
08000h-0FFFFh
Autoselect Mode
The autoselect mode provides manufacturer and de-
vice identification, and sector protection verification,
through identifier codes output on DQ7–DQ0. This
mode is primarily intended for programming equipment
to automatically match a device to be programmed with
its corresponding programming algorithm. However,
the autoselect codes can also be accessed in-system
through the command register.
When using programming equipment, the autoselect
mode requires VID (11.5 V to 12.5 V) on address pin
A9. Address pins A6, A1, and A0 must be as shown in
Autoselect Codes (High Voltage Method) table. In addi-
tion, when verifying sector protection, the sector
address must appear on the appropriate highest order
address bits. Refer to the corresponding Sector Ad-
dress Tables. The Command Definitions table shows
the remaining address bits that are don’t care. When all
necessary bits have been set as required, the program-
ming equipment may then read the corresponding
identifier code on DQ7–DQ0.
To access the autoselect codes in-system, the host
system can issue the autoselect command via the
command register, as shown in the Command Defini-
tions table. This method does not require VID. See
“Command Definitions” for details on using the autose-
lect mode.