Electrical Specifications
TA = -40oC to 85oC, VCC = +5V ±5%, VBH = -48V, VBL = -24V, PTG = Open, RP1 = RP2 = 0Ω, ZT = 120kΩ, RLIM = 38.3kΩ, RD = 50kΩ, RDC_RAC = 20kΩ,
ROH = 40kΩ, CH = 0.1µF, CDC = 4.7µF, CRT/REV = 0.47µF, GND = 0V, RL = 600Ω. Unless Otherwise Specified. (•) Symbol used to indicate the test applies
to the part. (NA) symbol used to indicate the test does not apply to the part.
PARAMETER
TEST CONDITIONS
2-WIRE PORT
Overload Level, Off Hook
Forward and Reverse
1% THD, IDCMET ≥ 18mA
(Note 2, Figure 1)
Overload Level, On Hook
Forward and Reverse
1% THD, IDCMET ≤ 5mA
(Note 3, Figure 1)
Input Impedance (Into Tip and Ring)
MIN
TYP
MAX
3.2
-
-
1.3
-
-
- ZT/200 -
UNITS
VPEAK
VPEAK
Ω
HC55120 HC55121 HC55130/1 HC55140/1 HC55142/3 HC55150/1
Forward
Only
•
Forward
Only
•
•
•
Forward
Only
•
Forward
Only
•
•
•
•
•
•
•
•
•
Longitudinal Impedance (Tip, Ring) 0 < f < 100Hz (Note 4, Figure 2)
Forward and Reverse
-
0
-
Ω/Wire
Forward
Only
•
Forward
Only
•
•
•
LONGITUDINAL CURRENT LIMIT (TIP, RING)
On-Hook, Off-Hook (Active),
No False Detections, (Loop
28
-
- mARMS/Wire Forward
Forward
RL = 736Ω
Current), LB > 45dB (Notes 5, 6,
Only
•
Only
•
•
•
Forward and Reverse
Figures 3A, 3B)
VTR
RL
IDCMET
TIP
VTX
ERX
RING VRX
FIGURE 1. OVERLOAD LEVEL (OFF HOOK, ON HOOK)
1VRMS
AT
TIP
VTX
0 < f < 100Hz
EL C
300Ω
VT
300Ω
AR
VR
RING
VRX
LZT = VT/AT
LZR = VR/AR
FIGURE 2. LONGITUDINAL IMPEDANCE
368Ω
A TIP
VTX
10µF C
EL
10µF C
368Ω
A RING VRX
SHD
FIGURE 3A. LONGITUDINAL CURRENT LIMIT ON-HOOK (ACTIVE)
368Ω
A TIP
VTX
C
VTX
EL
368Ω
A RING VRX
SHD
FIGURE 3B. LONGITUDINAL CURRENT LIMIT OFF-HOOK (ACTIVE)