Philips Semiconductors
CATV amplifier modules
Product specification
BGY586; BGY587
CHARACTERISTICS
Bandwidth 40 to 550 MHz; VB = 24 V; Tmb = 30 °C; ZS = ZL = 75 Ω.
SYMBOL
PARAMETER
CONDITIONS
Gp
SL
FL
S11
S22
S21
CTB
Xmod
CSO
d2
Vo
F
Itot
power gain
slope cable equivalent
flatness of frequency response
input return losses
output return losses
phase response
composite triple beat
BGY586
BGY587
cross modulation
BGY586
BGY587
composite second order distortion
BGY586
BGY587
second order distortion
BGY586
BGY587
output voltage
BGY586
BGY587
noise figure
BGY586
BGY587
total current consumption (DC)
BGY586
BGY587
f = 50 MHz
f = 550 MHz
f = 40 to 550 MHz
f = 40 to 550 MHz
f = 40 to 80 MHz
f = 80 to 160 MHz
f = 160 to 550 MHz
f = 40 to 80 MHz
f = 80 to 160 MHz
f = 160 to 550 MHz
f = 50 MHz
77 channels flat;
Vo = 44 dBmV;
measured at 547.25 MHz
77 channels flat;
Vo = 44 dBmV;
measured at 55.25 MHz
77 channels flat;
Vo = 44 dBmV;
measured at 548.5 MHz
note 1
dim = −60 dB; note 2
f = 550 MHz
note 3
MIN.
21.5
22
0.2
−
20
19
18
20
19
18
+135
TYP.
−
−
−
−
−
−
−
−
−
−
−
MAX. UNIT
22.5 dB
−
dB
1.5
dB
±0.2 dB
−
dB
−
dB
−
dB
−
dB
−
dB
−
dB
+225 deg
−
−
−53 dB
−
−
−57 dB
−
−
−55 dB
−
−
−58 dB
−
−
−50 dB
−
−
−54 dB
−
−
−62 dB
−
−
−66 dB
58.5 −
−
dBmV
61
−
−
dBmV
−
−
6.5
dB
−
−
7
dB
−
180 200 mA
−
220 240 mA
Notes
1. fp = 55.25 MHz; Vp = 44 dBmV; fq = 493.25 MHz; Vq = 44 dBmV; measured at fp + fq = 548.5 MHz.
2. Measured according to DIN45004B: fp = 540.25 MHz; Vp = Vo; fq = 547.25 MHz; Vq = Vo −6 dB;
fr = 549.25 MHz; Vr = Vo −6 dB; measured at fp + fq − fr = 538.25 MHz.
3. The modules normally operate at VB = 24 V, but are able to withstand supply transients up to 30 V.
February 1995
3