DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AM79489 データシートの表示(PDF) - Unspecified

部品番号
コンポーネント説明
メーカー
AM79489 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
RELAY DRIVER SCHEMATICS
RINGOUT
TESTOUT
BGND
BGND
Notes:
1. Unless otherwise specified, test conditions are VCC = +5 V, BAT1 = 50 V, BAT2 = 34 V, RL = 600 , RDC1 = RDC2 = 5.833 k,
RTMG = 570 , RD = 35.4 k, RFA = 0 , no fuse resistors, CHP = 0.22 µF, CDC = 0.5 µF, CCAS = 0.33 µF, CVBAT12 = 220 nF,
D1 = D2 = 1N400x, OVH = 1, two-wire AC input impedance is a 600 resistance synthesized by the programming network
shown below.
VTX
RT1 = 76 k
RT2 = 76 k
CT1 = 120 pF
RSN
RRX = 150 k
VRX
2. a. Overload level exists when THD = 1%.
b. Overload level exists when THD = 1.5%.
3. This parameter is tested at 1 kHz in production. Performance at other frequencies is guaranteed by characterization.
4. Not tested in production. This parameter is guaranteed by characterization or correlation to other tests.
5. Tested with 0 source impedance. 2 Mis specified for system design only.
6. Group delay can be greatly reduced by using a ZT network such as that shown in Note 1 above. The network reduces the
group delay to less than 2 µs and increases 2WRL. The effect of group delay on linecard performance also may be
compensated for by synthesizing complex impedance with the DSLACor QSLACdevice.
7. Minimum current level is guaranteed not to cause a false Loop Detect. The SLIC must be functional in this condition.
8. Four-wire performance is 59 dB better than the specified two-wire values.
9. Open loop, Active state, Metering mode power dissipation may be reduced from a typical of 550 mW to a typical of 150 mW
by connecting the DET pin to the OVH pin. This connection will force the SLIC into the nonmetering mode while on hook. With
this connection, a metering signal sent after the SLIC goes on hook may be distorted on the 2W line because the SLIC is
forced into the nonmetering mode. To eliminate this distortion, a delay can be added between the time the SLIC goes on hook
and the time the SLIC switches to nonmetering mode by using an RC circuit for the DET pin to OVH pin connection.
SLIC Products
9

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]