IMX15, IMY15, IMS15 Series Data Sheet
15 Watt DC-DC Converters
RoHS-Compliant Models
The type designation of RoHS-compliant models (compliant for the restriction of all six substances) for the IMX/IMY15 Series ends
with "G".
However, in single-output models with 3.3 V or 5.1 V output an extra hyphen (-) is added after the existing "G", which already
signifies a synchronous rectifierSR. This is an exception to our normal nomenclature to identify this type of product, since G is
already used to designate products for higher output current fitted with a synchronous rectifier. Some examples
– 20IMX15-05-8R-G designates a standard version with RoHS compliance for all six substances.
– 20IMX15-05-8RG designates a synchronous rectifierSR version which is not RoHS-compliant.
– 20IMX15-05-8RG-G designates a synchronous rectifierSR version and RoHS compliant for all six substances.
– 20IMX15-05-05-8G designates a double-output model with RoHS compliance for all six substances
– 110IMY15-24-24-8RG designates a double-output model with RoHS compliance for all six substances.
Part Number Description
xxix
Input voltage range Vi
8.4 to 36 V ...................................................... 20
14 to 36 V ....................................................... 24
16.8 to 75 V .................................................... 40
36 to 75 V ....................................................... 48
50 to 150 V ................................................... 110
Series
IMX15, IMS15, IMY15
Output voltage of output 1 ............................ 03, 05, 12, 15, 24
Hyphen designating double-output models with two
electrically isolated outputs ............................... - 1
Output voltage of output 2 ............................ 03, 05, 12, 15, 24
Operating ambient temperature range TA
– 40 6 to 85 °C .................................................. -8 6
– 40to 71 °C ..................................................... -9 2
Options and features:
R input and magnetic feedback ....................... R 3
Synchronous rectification ................................ G
Inhibit ................................................................. i 4
Open frame ...................................................... Z
RoHS-compliant for all6 substances ........ G or -G 5
1 Not applicable to -0503 models. They have a common ground.
2 IMS15 models are not recommended for new designs.
3 Standard for single-output and -0503 models
4 Option i replaces the standard shutdown function; see Description of Options.
5 RoHS models with synchronous rectifier end as an exception with -G.
6 Only –25 °C for older -8RGSR models (Rev. < BA); see table 7a.
Note: The sequence of options must follow the order above !
40 IMX15 - 05 - 8 R G Z -G
Examples:
20 IM X15-05-05-8G: DC-DC converter, input 9 to 36 V, 2 galvanically isolated outputs each providing 5 V, 1.3 A,
RoHS-compliant
110 IMY15-0503-8RG: DC-DC converter, input 50 to 150 V, 2 outputs with common return providing +5.1 V, 1.5 A and
+3.3 V, 1.5 A, RoHS-compliant. Converter fitted with magnetic feedback for tight output voltage regulation.
Product Marking
The converters without option Z are marked with basic type designation, input and output voltages and currents, applicable safety
approval and recognition marks, patent nos., company logo, date code, and serial number.
BCD20008-G Rev AE, 25-Aug-2017
MELCHER
The Power Partners.
Page 3 of 19