CGY 196
Determination of Permissible Total Power Dissipation for Continuous and Pulse
Operation
The dissipated power is the power which remains in the chip and heats the device. It does
not contain RF signals which are coupled out consistently.
a) Continuous Wave / DC Operation
For the determination of the permissible total power dissipation Ptot-DC from the diagram
below it is necessary to obtain the temperature of the soldering point TS first. There are two
cases:
When RthSA (soldering point to ambient) is not known: Measure TS with a temperature
sensor at the leads were the heat is transferred from the device to the board ( normally at
the widest source or ground lead for GaAs ). Use a small sensor of low heat transport,
for example a thermoelement ( < 1mm ) with thin wires or a temperature indicating paper
while the device is operating.
When RthSA is already known:
TS = Pdiss x RthSA + TA
mW
1600
1400
1200
1000
800
600
400
200
0
0
Permissible Total Power Dissipation in DC Operation
Ptot DC = f (Ts)
75
25
50
75
100
Temperature of soldering point, Ts
125
150
°C