TS391, TS391A
Absolute maximum ratings and operating
conditions
3
Absolute maximum ratings and operating conditions
Symbol
Table 1: Absolute maximum ratings (AMR)
Parameter
Value
Unit
VCC
Vid
Vi
Vo
Tj
Tstg
Rthja
ESD
Supply voltage
Differential input voltage
Input voltage
Output voltage (1)
Output short-circuit to ground (2)
Maximum junction temperature
Storage temperature range
Thermal resistance junction to ambient (3)
Human body model (HBM) (4)
Machine model (MM) (5)
Charged device model (CDM) (6)
SOT23-5
DFN8 2x2
±18 or 36
±36
-0.3 to 36
36
Infinite
150
-65 to 150
250
57
1500
100
1000
V
°C
°C/W
V
Notes:
(1)Output voltage can be set up to 36 V even if the VCC is lower.
(2)Short-circuits from the output to VCC+ can cause excessive heating and potential destruction. The maximum
output current is approximately 20 mA independent of the magnitude of VCC+.
(3)Short-circuits can cause excessive heating. These values are typical.
(4)Human body model: a 100 pF capacitor is charged to the specified voltage, then discharged through a 1.5 kΩ
resistor between two pins of the device. This is done for all couples of connected pin combinations while the other
pins are floating.
(5)Machine model: a 200 pF capacitor is charged to the specified voltage, then discharged directly between two
pins of the device with no external series resistor (internal resistor < 5 Ω). This is done for all couples of connected
pin combinations while the other pins are floating.
(6)Charged device model: all pins and package are charged together to the specified voltage and then discharged
directly to ground through only one pin. This is done for all pins.
Symbol
VCC
Vicm
Toper
Table 2: Operating conditions
Parameter
Supply voltage
Input common mode voltage range (1)
Operating free-air temperature range
Tamb = 25 °C
Tmin Tamb Tmax
Value
2 to 36 or ±1 to ±18
0 to (VCC+) - 1.5
0 to (VCC+) - 2
-40 to 125
Unit
V
°C
Notes:
(1)The input common-mode voltage of either input signal voltage should not be allowed to go negative by more
than 0.3 V. The upper end of the common-mode voltage range is (VCC+) 1.5 V, but either or both inputs can go
to 30 V without damage.
DocID6324 Rev 8