DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ICS503 データシートの表示(PDF) - Integrated Device Technology

部品番号
コンポーネント説明
メーカー
ICS503
IDT
Integrated Device Technology IDT
ICS503 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
ICS503
LOCO™ PLL CLOCK MULTIPLIER
CLOCK MULTIPLIER
External Components
Decoupling Capacitor
As with any high-performance mixed-signal IC, the
ICS503 must be isolated from system power supply
noise to perform optimally.
A decoupling capacitor of 0.01µF must be connected
between VDD and GND. It must be connected close to
the ICS503 to minimize lead inductance. No external
power supply filtering is required for the ICS503.
Series Termination Resistor
A 33terminating resistor can be used next to the CLK
pin. The total on-chip capacitance is approximately 12
pF. A parallel resonant, fundamental mode crystal
should be used.
Crystal Load Capacitors
The device crystal connections should include pads for
small capacitors from X1 to ground and from X2 to
ground. These capacitors are used to adjust the stray
capacitance of the board to match the nominally
required crystal load capacitance. Because load
capacitance can only be increased in this trimming
process, it is important to keep stray capacitance to a
minimum by using very short PCB traces (and no vias)
between the crystal and device. Crystal capacitors, if
needed, must be connected from each of the pins X1
and X2 to ground.
The value (in pF) of these crystal caps should equal (CL
-12 pF)*2. In this equation, CL= crystal load capacitance
in pF. Example: For a crystal with a 16 pF load
capacitance, each crystal capacitor would be 8 pF
[(16-12) x 2] = 8.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS503. These ratings, which
are standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the
device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature
Storage Temperature
Soldering Temperature
Rating
7V
-0.5 V to VDD+0.5 V
0 to +70° C
-65 to +150° C
260° C
Recommended Operation Conditions
Parameter
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
Min.
0
+3
Typ.
Max.
+70
+5.5
Units
°C
V
IDT™ / ICS™ LOCO™ PLL CLOCK MULTIPLIER
4
ICS503
REV D 051310

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]