DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-M60L データシートの表示(PDF) - Broadcom Corporation

部品番号
コンポーネント説明
メーカー
ACPL-M60L Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ACPL-M60L
Data Sheet
Solder Reflow Profile
The recommended reflow soldering conditions are per JEDEC Standard J-STD-020 (latest revision). Non-halide flux should be used.
Insulation and Safety-Related Specifications
Parameter
Minimum External Air Gap (Clearance)
Minimum External Tracking Path (Creepage)
Minimum Internal Plastic Gap (Clearance)
Tracking Resistance
Isolation Group (per DIN VDE 0109)
Symbol
L (I01)
L (I02)
CTI
Value
5
5
0.08
175
IIIa
Units
Conditions
mm Measured from input terminals to output terminals
mm Measured from input terminals to output terminals
mm Through insulation distance, conductor to conductor
V DIN IEC 112/VDE 0303 Part 1
Material Group DIN VDE 0109
IEC/EN/DIN EN 60747-5-5 Insulation Characteristicsa (Option x60E)
Description
Symbol Characteristic
Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method ba
VIORM × 1.875=VPR, 100% Production Test with tm=1s, Partial discharge < 5 pC
Input to Output Test Voltage, Method aa
VIORM × 1.6=VPR, Type and Sample Test, tm=10s, Partial discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage tini = 60s)
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
VIORM
VPR
VPR
VIOTM
TS
IS, INPUT
PS, OUTPUT
RS
I - IV
I - IV
I - III
55/100/21
2
567
1063
907
6000
175
150
600
>109
Vpeak
Vpeak
Vpeak
Vpeak
°C
ms
mW
Ω
a. Refer to the optocoupler section of the Isolation and Control Components Designer's Catalog, under Product Safety Regulations section, (IEC/EN/DIN EN
60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
NOTE These optocouplers are suitable for safe electrical isolation only within the safety limit data. Maintenance of the
safety limit data shall be ensured by means of protective circuits.
Broadcom
-4-

Share Link: 