ACPL-M49T
Data Sheet
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision).
NOTE Non-halide flux should be used.
Regulatory Information
The ACPL-M49T is approved by the following safety regulatory organizations.
UL
Approved under UL 1577, component recognition program up to VISO = 4000 VRMS
CSA
Approved under CSA Component Acceptance Notice #5.
IEC/EN/DIN EN 60747-5-5 EC 60747-5-5
EN 60747-5-5
DIN EN 60747-5-5
IEC/EN/DIN EN 60747-5-5 Insulation Characteristicsa
Description
Symbol
Characteristic
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method ba
VIORM × 1.875 = VPR, 100% Production Test with tm = 1s, Partial discharge < 5 pC
Input to Output Test Voltage, Method aa
VIORM × 1.6 = VPR, Type and Sample Test, tm = 10s, Partial discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage tini = 60s)
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500V
VIORM
VPR
VPR
VIOTM
TS
IS, INPUT
PS, OUTPUT
RS
I – IV
I – III
I – II
40/125/21
2
567
1063
907
6000
175
230
600
>109
Vpeak
Vpeak
Vpeak
Vpeak
°C
mA
mW
a. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN EN
60747-5-5) for a detailed description of Method a and Method b partial discharge test profi les.
Broadcom
-4-