■RELIABILITY DATA
1. Terminal stregth
Specified Value No damage to be found.
Bending Test.
according to IEC60068-2-21(JISC60068-2-21)
Test Methods and
Remarks
2. Mechanical shock
Specified Value After testing, meet the specified characteristics at a room temperature.
Test Methods and Apply 14700m/s2 for 0.5ms 5 times for each of 6 directions.
Remarks
according to IEC68-2-27(JISC60068-2-27).
3. Vibration
Specified Value
Test Methods and
Remarks
After testing, meet the specified characteristics at a room temperature.
With 1.5 mm of whole amplitude at 10 to 55 Hz of frequency, and 98m/s2 of acceleration at 55 to 500Hz, apply a
vibration for 2 hours for each of 3 directions, period is 15 minutes(10 to 500 to 10Hz)
4. Drop 1
Specified Value
Test Methods and
Remarks
After testing, meet the specified characteristics at a room temperature.
Drop 3 times onto concrete floor from the height of 1.0m.
5. Drop 2
Specified Value
Test Methods and
Remarks
After testing, meet the specified characteristics at a room temperature.
Drop with 150g weight 3 times in each 6 direction onto concrete floor from the height of 1.8m.
6. Temperature cycling
Specified Value After testing, meet the specified characteristics at a room temperature.
Test Methods and
Remarks
Temp. range -40 to +100℃. 500cycle.
7. Static humidity
Specified Value
Test Methods and
Remarks
After testing, meet the specified characteristics at a room temperature.
+85℃, 90% to 95%RH, apply DC5V, 1000hours.
8. High temperature storage life
Specified Value After testing, meet the specified characteristics at a room temperature.
Test Methods and
+100℃, 1000hours.
Remarks
9. Low temperature storage life
Specified Value After testing, meet the specified characteristics at a room temperature.
Test Methods and
-40℃, 1000hours.
Remarks