DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HLMP-1540 データシートの表示(PDF) - Broadcom Corporation

部品番号
コンポーネント説明
メーカー
HLMP-1540 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
HLMP-3707, HLMP-3907, HLMP-3750, HLMP-3850, HLMP-3950, HLMP-3960,
HLMP-3390, HLMP-3490, HLMP-3590, HLMP-1340, HLMP-1440, HLMP-1540,
HLMP-K640 Data Sheet
Selection Guide
T-1 3/4 (5 mm), T-1 (3 mm), Ultra-Bright LED Lamps
Package
Description
T-1 3/4
Color
Red
Yellow
Green
T-1 3/4 Low Profile
T-1
Red
Yellow
Green
Red
Yellow
Green
Emerald Green
Device HLMP-
3707-L00xx
3750
3750-L00xx
3850
3850-K00xx
3907-K00xx
3914
3950
3950-K00xx
3950-LM000
3960-K0xxx
3950-MNC00
3390
3490
3590
1340
1340-J00xx
1440
1440-H00xx
1440-HJ000
1440-IJB00
1540
1540-H00xx
1540-IJ000
K640
Luminous Intensity Iv (mcd) @ 20 mA
Min.
90.2
90.2
90.2
96.2
96.2
111.7
111.7
111.7
111.7
170.0
111.7
245.0
35.2
37.6
43.6
35.2
35.2
23.5
23.5
23.5
37.6
27.3
27.3
43.6
4.2
Typ.
125.0
125.0
140.0
140.0
265.0
265.0
300.0
265.0
490.0
55.0
55.0
55.0
55.0
55.0
45.0
45.0
45.0
75.0
45.0
45.0
60.0
21.0
Max.
490.0
760.0
120.2
120.2
139.6
21/2 Degree
24
24
24
24
24
24
24
24
24
24
24
24
32
32
32
45
45
45
45
45
45
45
45
45
45
Package
Outline
F
A
A
A
A
F
D
A
A
A
E
A
B
B
B
C
C
C
C
C
C
C
C
C
C
Absolute Maximum Ratings at TA = 25°C
Parameter
Red
Yellow
Green/Emerald Green
Units
Peak Forward Current
90
60
90
mA
Average Forward Currenta
25
20
25
mA
DC Currentb
30
20
30
mA
Transient Forward Currentc (10-µs Pulse)
500
500
500
mA
Reverse Voltage (IR = 100 µA)
5
5
5
V
LED Junction Temperature
110
110
110
°C
Operating Temperature Range
–40 to +100
–40 to +100
–20 to +100
°C
Storage Temperature Range
–40 to +100
–40 to +100
–40 to +100
°C
a. See Figure 8 to establish pulsed operating conditions.
b. For Red and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
c. The transient peak current is the maximum non-recurring peak current the devices can withstand without damaging the LED die and wire