DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-W480-060E データシートの表示(PDF) - Broadcom Corporation

部品番号
コンポーネント説明
メーカー
ACPL-W480-060E Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
ACPL-P480 and ACPL-W480
Data Sheet
Package Characteristics
Parameter
Symbol
Min.
Typ. Max. Unit
Test Conditions
Fig.
Note
Input-Output Momentary
VISO
Withstand Voltagea
3750b
5000c
VRMS
RH < 50%, t = 1 min.
5, 6
TA = 25°C
Input-Output Resistance
RI-O
1012
VI-O = 500VDC
5
Input-Output Capacitance
CI-O
0.6
f = 1 MHz, VI-O = 0VDC
5
a. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating.
For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-5 Insulation Characteristics Table (if applicable).
b. For all ACPL-P480 devices except Option 020.
c. For ACPL-W480 and Option 020 of ACPL-P480)
Notes:
1. The tPLH propagation delay is measured from the 50% point on the leading edge of the input pulse to the 1.3V point on the leading edge of
the output pulse. The tPHL propagation delay is measured from the 50% point on the trailing edge of the input pulse to the 1.3V point on
the trailing edge of the output pulse.
2. Pulse Width Distortion (PWD) is defined as |tPHL – tPLH | for any given device.
3. The difference between tPLH and tPHL between any two devices under the same test condition.
4. CMH is the maximum slew rate of the common mode voltage that can be sustained with the output voltage in the logic high state, VO > 2.0V.
CML is the maximum slew rate of the common mode voltage that can be sustained with the output voltage in the logic low state, VO < 0.8V.
5. Device considered a two-terminal device: pins 1, 2, and 3 shorted together and pins 4, 5, and 6 shorted together.
6. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage 4500VRMS for one second (leakage
detection current limit, II-O ≤ 5 μA); each optocoupler with option 020 is proof tested by applying an insulation test voltage. 6000VRMS for
1 second (leakage detection current limit, II-O ≤ 5 μA). This test is performed before the 100% production test for partial discharge (Method
b) shown in the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table, if applicable.
7. Use of a 0.1 μF bypass capacitor connected between pins 4 and 6 is recommended.
Broadcom
-7-

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]