Specifications HS-0506RH, HS-0507RH
Device tested Per Table 1.
TABLE 5. BURN-IN DELTA PARAMETERS (TA = +25oC)
PARAMETERS
SYMBOL
Input Leakage Current
IIH, IIL
Leakage Current into the Source Terminal of an ‘‘OFF’’ Switch
+IS(OFF)
-IS(OFF)
Leakage Current into the Drain Terminal of an ‘‘OFF’’ Switch
+ID(OFF)
-ID(OFF)
Leakage Current from an ‘‘ON’’ Driver into the Switch (Drain)
+ID(ON)
-ID(ON)
Switch On Resistance
R(DS)
R(DS)
Positive Supply Current
I(+)
Negative Supply Current
I(-)
Positive Standby Supply Current
+ISBY
Negative Standby Supply Current
-ISBY
DELTA LIMITS
±100nA
±10nA
±10nA
±10nA
±10nA
±10nA
±10nA
±50Ω
±50Ω
± 300µA
± 100µA
± 300µA
± 100µA
TABLE 6. APPLICABLE SUBGROUPS
GROUP A SUBGROUPS
CONFORMANCE GROUPS
MIL-STD-883 METHOD
TESTED FOR -Q
RECORDED FOR -Q
Initial Test
100% 5004
1, 9
1 (Note 2)
Interim Test
100% 5004
1, 9, ∆
1, ∆ (Note 2)
PDA
100% 5004
1, ∆
−
Final Test
100% 5004
2, 3, 10, 11
-
Group A (Note 1)
Sample 5005
1, 2, 3, 9, 10, 11
-
Subgroup B5
Sample 5005
1, 2, 3, ∆
1, 2, 3, ∆ (Note 2)
Subgroup B6
Sample 5005
1
-
Group D
Sample 5005
1
-
Group E, Subgroup 2
Sample 5005
1
-
NOTES:
1. Alternate Group A testing in accordance with MIL-STD-883 Method 5005 may be exercised.
2. Table 5 parameters only.
Spec Number 518860
7