PRELIMINARY
CY7C1046BV33
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage on VCC to Relative GND[1] .... –0.5V to +4.6V
DC Voltage Applied to Outputs
in High Z State[1] ....................................–0.5V to VCC + 0.5V
DC Input Voltage[1] ................................–0.5V to VCC + 0.5V
Electrical Characteristics Over the Operating Range
Current into Outputs (LOW) ........................................ 20 mA
Static Discharge Voltage ........................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current..................................................... >200 mA
Operating Range
Range
Commercial
Ambient
Temperature[2]
0°C to +70°C
VCC
3.0V - 3.6V
7C1046BV33-10 7C1046BV33-12 7C1046BV33-15
Parameter
Description
Test Conditions
Min. Max. Min. Max. Min. Max. Unit
VOH
Output HIGH Voltage VCC = Min., IOH = –4.0 mA 2.4
2.4
2.4
V
VOL
Output LOW Voltage VCC = Min., IOL = 8.0 mA
0.4
0.4
0.4 V
VIH
Input HIGH Voltage
2.2
VCC
2.2
VCC
2.2
VCC V
+ 0.5
+ 0.5
+ 0.5
VIL
Input LOW Voltage[1]
–0.5 0.8 –0.5 0.8 –0.5 0.8 V
IIX
Input Load Current GND < VI < VCC
–1
+1
–1
+1
–1
+1 µA
IOZ
Output Leakage
GND < VOUT < VCC,
Current
Output Disabled
–1
+1
–1
+1
–1
+1 µA
ICC
VCC Operating
VCC = Max.,
Supply Current
f = fMAX = 1/tRC
150
140
130 mA
ISB1
Automatic CE
Max. VCC, CE > VIH
Power-Down Current VIN > VIH or
—TTL Inputs
VIN < VIL, f = fMAX
20
20
20 mA
ISB2
Automatic CE
Max. VCC,
Com’l
8
8
8 mA
Power-Down Current
—CMOS Inputs
CE > VCC – 0.3V,
VIN > VCC – 0.3V,
L version
0.5
0.5
0.5
or VIN < 0.3V,
f=0
Shaded areas contain advance information.
Capacitance[3]
Parameter
Description
Test Conditions
CIN
COUT
Input Capacitance
I/O Capacitance
TA = 25°C, f = 1 MHz,
VCC = 3.3V
Notes:
1. VIL (min.) = –2.0V for pulse durations of less than 20 ns.
2. TA is the “Instant On” case temperature.
3. Tested initially and after any design or process changes that may affect these parameters.
Max.
Unit
6
pF
6
pF
Document #: 38-05170 Rev. **