ADXL356/ADXL357
Data Sheet
Parameter
Repeatability2
VRE4
NOISE
Spectral Density5
X-Axis, Y-Axis, and Z-Axis
Velocity Random Walk
X-Axis and Y-Axis
Z-Axis
BANDWIDTH AND OUTPUT DATA RATE
Analog-to-Digital Converter (ADC) Resolution
Low-Pass Filter Passband Frequency
High-Pass Filter Passband Frequency When
Enabled (Disabled by Default)
SELF TEST
Output Change
Z-Axis
POWER SUPPLY
Voltage Range
VSUPPLY Operating7
VDDIO
V1P8ANA and V1P8DIG
Current
Measurement Mode
VSUPPLY
V1P8ANA
V1P8DIG
Standby Mode
VSUPPLY
V1P8ANA
V1P8DIG
Turn On Time8
TEMPERATURE SENSOR
Output at 25°C
Scale Factor
TEMPERATURE
Operating Temperature Range
Test Conditions/Comments
X-axis and y-axis
Z-axis
Offset due to 7.5 g rms vibration, ±10 g
range, in a 1 g orientation
Min Typ Max Unit
±4.25
mg
±5
mg
<0.1
g
±10 g
75
±40 g
90
±10 g
38.2
26.5
User programmable, Register 0x28
User programmable, Register 0x28 for 4 kHz
ODR
20
0.977
0.0095
μg/√Hz
μg/√Hz
mm/sec/Hr
mm/sec/Hr
Bits
1000 Hz
10
Hz
±10 g range6
0.5
1.25 3.0
g
2.25 2.5
V1P8DIG 2.5
Internal LDO regulator bypassed, VSUPPLY = 0 V 1.62 1.8
3.6
V
3.6
V
1.98 V
LDO regulator enabled
LDO regulator disabled
LDO regulator disabled
LDO regulator enabled
LDO regulator disabled
LDO regulator disabled
±10 g range
Power-off to standby
200
μA
160
μA
35.5
μA
21
μA
7
μA
10
μA
<10
ms
<10
ms
1885
−9.05
LSB
LSB/°C
−40
+125 °C
1 Characterized but not 100% tested.
2 Repeatability is predicted for a 10 year life and includes shifts due to the HTOL (TA = 150°C, VSUPPLY = 3.6 V, and 1000 hours), temperature cycling (−55°C to +125°C and
1000 cycles), velocity random walk, broadband noise, and temperature hysteresis. Repeatability in relation to time follows the square root law. For example, to obtain
offset repeatability of the x-axis for 2.5 years, use the following equation: ±4.25 mg × √(2.5 years/10 years) = ±2.125 mg.
3 The temperature change is −40°C to +25°C or +25°C to +125°C.
4 The VRE measurement is the shift in dc offset while the device is subject to 7.5 g rms random vibration from 50 Hz to 2 kHz. The DUT is configured for the ±10 g range
and an output data rate of 4 kHz. The VRE scales with the range setting.
5 Based on characterization.
6 ±10 g indicates a test condition. The self test result converted to the acceleration value is independent of the selected range.
7 When V1P8ANA and V1P8DIG are generated internally, VSUPPLY is valid. To disable the LDO regulator and drive V1P8ANA and V1P8DIG externally, connect VSUPPLY to VSS.
8 Standby to measurement mode. This specification is valid when the output is within 1 mg of final value.